REPLACING POWER CIRCUIT BREAKER
1) Place the CooLift on a level flooring surface and engage the holding brake.
2) Turn off main power switch.
3) Disconnect the wiring connections from the back of the
connect to the new circuit breaker making sure to follow the same connection layout.
4) When all of the new connections have been made, the damaged circuit breaker should be able
to be removed by grasping it firmly in one hand and removing the hex nut on the outside of the
enclosure shelf with the 17mm wrench.
5) Note the locations of the backup hex nut, the locking ring and the lock washer on the damaged
unit and replicate it on the new replacement component.
6) Hold the replacement circuit breaker in place on the enclosure shelf and tighten the hex nut on the
outside with the 17mm wrench.
7) Recheck all connections for correct wiring placement and tightness. Reconnect the batteries.
Hex nut
1-800-MAGLINE (624-5463)
TOOLS NEEDED: 17mm WRENCH
Remove back panel.
Page 23
Disconnect the batteries.
damaged circuit breaker one at a time and
Item
Circuit breaker
CooLift
®
Part
Number
62037