5. Digital Controller

5.1 Operation

When power is applied to the control, the control will configure itself to operate in accordance
with the parameters stored in memory. These parameters may be adjusted using Manager's Mode.
Unplug griddle from wall receptacle before replacing the
control board in order to prevent damage to equipment.
Operating Mode
When power is applied to the control, the control will configure itself to operate in accordance
with the parameters stored in memory. These parameters may be adjusted using Manager's Mode.
Reset
Pressing and holding the DOWN (S4) arrow key and the ON/OFF (S5) key for five seconds will reset
the software back to the factory default settings.
Error Codes
The control will display error codes for the following conditions:
E001 Displays when controller detects an Open Sensor
E002 Displays when controller detects a Shorted Sensor
9999 No calibration data stored or invalid calibration data detected
To reset from any error, unit must be turned OFF, repaired, and then turned ON.
When any error is displayed, outputs are forced open. The following section illustrates the
programming logic and program level indication: