AccuTemp ACCU-STEAM G2 Series Service Manual page 13

Gas griddle
Hide thumbs Also See for ACCU-STEAM G2 Series:
Table of Contents

Advertisement

Fault light
flashing
F
Fault light on •
G
YEL
VIO
WHT/BRN
BRN
L1 L2
N.C. N.O. COM *RTD*
BRN
RED
BRN
OVER
TEMP
AT0E-3880-1
SP8042-1911
HI-LIMIT CONTROL
If burners did not ignite, check gas pressure, cycle power.
If burners ignite briefly and then fault light is displayed, cycle power and
verify flame sense. See section 8.3.1 Flame Sense for more information.
If burners did ignite and unit is heating, check for poor connections in the
harness at the fault timer relay (Fig 4.C).
Ensure that chassis ground connection is tight.
If burners did not ignite, replace fault timer.
If burners did ignite and unit heating, check for short to ground in the white
wire connected to the fault indicator lamp.
AT2B-2099-2
AT2B-2131-2
AT0E-2885-7
HI-LIMIT SENSOR
100 O
PRTD
WHT/GRAY
WHT/BRN
ORN
VIO
BRN
1
2
1
RESET
J2
POWER
INPUT
HIGH LIMIT
+24V
CONTROLLER
GND
Accu-Steam™ G2 Gas Service Manual
AT2E-1806-3
PROPANE CONTROL VALVE
RED
BWN
AT2E-4717-1
FLAME SENSE PROBE
36"& 48"
BURNER
BURNER
24"
BURNER
Fig 4.C
AT0E-2885-8
TEMPERATURE SENSOR
1000O
PRTD
GRY
2
3
4
5
6
1
2
1
2
3
J7
J3
ISSP
SENSOR
INPUT
ON/
DIGITAL
OFF
CONTROLLER
AT0E-3625-5
Control Board
AT2E-1806-2
NG CONTROL VALVE
YEL
ZR1
MV
38V
GAS VALVE
ZR2
PV
38V
AT2E-4716-1
HV IGNITOR
IGNITOR
YEL
SPARK
MODULE
6
ORN
5
GRN
4
3
BLU
2
RED
1
AT2E-1807-1
IGNITION CONTOL MODULE
8
7
N.O.
BLU
COM
3
4
5
5
1
N.C.
N.O.
AT0E-2825-6
4
Relay, DC
6
COM
2
RLY 2
N.C.
DC COIL
AccuTemp Products, Inc.
8415 N. Clinton Park
Fort Wayne, IN 46825
MAIN VALVE
PILOT VALVE