Fault light
flashing
F
Fault light on •
G
YEL
VIO
WHT/BRN
BRN
L1 L2
N.C. N.O. COM *RTD*
BRN
RED
BRN
OVER
TEMP
AT0E-3880-1
SP8042-1911
HI-LIMIT CONTROL
•
If burners did not ignite, check gas pressure, cycle power.
•
If burners ignite briefly and then fault light is displayed, cycle power and
verify flame sense. See section 8.3.1 Flame Sense for more information.
•
If burners did ignite and unit is heating, check for poor connections in the
harness at the fault timer relay (Fig 4.C).
•
Ensure that chassis ground connection is tight.
If burners did not ignite, replace fault timer.
•
If burners did ignite and unit heating, check for short to ground in the white
wire connected to the fault indicator lamp.
AT2B-2099-2
AT2B-2131-2
AT0E-2885-7
HI-LIMIT SENSOR
100 O
PRTD
WHT/GRAY
WHT/BRN
ORN
VIO
BRN
1
2
1
RESET
J2
POWER
INPUT
HIGH LIMIT
+24V
CONTROLLER
GND
Accu-Steam™ G2 Gas Service Manual
AT2E-1806-3
PROPANE CONTROL VALVE
RED
BWN
AT2E-4717-1
FLAME SENSE PROBE
36"& 48"
BURNER
BURNER
24"
BURNER
Fig 4.C
AT0E-2885-8
TEMPERATURE SENSOR
1000O
PRTD
GRY
2
3
4
5
6
1
2
1
2
3
J7
J3
ISSP
SENSOR
INPUT
ON/
DIGITAL
OFF
CONTROLLER
AT0E-3625-5
Control Board
AT2E-1806-2
NG CONTROL VALVE
YEL
ZR1
MV
38V
GAS VALVE
ZR2
PV
38V
AT2E-4716-1
HV IGNITOR
IGNITOR
YEL
SPARK
MODULE
6
ORN
5
GRN
4
3
BLU
2
RED
1
AT2E-1807-1
IGNITION CONTOL MODULE
8
7
N.O.
BLU
COM
3
4
5
5
1
N.C.
N.O.
AT0E-2825-6
4
Relay, DC
6
COM
2
RLY 2
N.C.
DC COIL
AccuTemp Products, Inc.
8415 N. Clinton Park
Fort Wayne, IN 46825
MAIN VALVE
PILOT VALVE
12