Page 2
Notice The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS"...
Only manual adjustment is supported in the upstream direction. You can directly set the attenuation and equalization values in the upstream direction of the frequency mixer. 6.1 Configuring Manual Intelligent RF Adjustment (MA5833-BS60) 6.2 Configuring Automatic Intelligent RF Adjustment (DOCSIS 3.1)
Page 24
If a reverse amplifier is installed on a line: Input power of the RF port = Output value of the reverse amplifier – Attenuation from the reverse amplifier to the RF port of the MA5833-BS60 If no reverse amplifier is installed on a line: Input power of the RF port = Tx power of the CM –...
Page 28
0 downstream index 2 freq-width 6000 frequency 302 type doc-scqam Configure the attenuation of the upstream RF port of the upstream combiner. huawei(config)#cable rf-power 0 upstream group 1 attenuation 2 equalizer 2 huawei(config)#cable rf-power 0 upstream group 2 attenuation 2 equalizer 2 Issue 01 (2018-12-12)
6 Configuring Intelligent RF Adjustment Query the downstream RF transmit power monitoring information of all configured frequencies. huawei(config)#display cable rf-power-monitor 0 downstream status group 1 all huawei(config)#display cable rf-power-monitor 0 downstream status group 2 all 10. Query the downstream RF power adjustment log.