Huawei MA5833-BS60 Commissioning Manual page 28

Table of Contents

Advertisement

MA5833-BS60
Hardware Commissioning Guide
l
l
l
l
l
l
l
Example
1.
2.
3.
4.
5.
6.
7.
8.
Issue 01 (2018-12-12)
Monitoring frequencies:
Index
1
2
Upstream supports 6 DOCSIS 3.0 channels, spectrum range: 5-85 MHz
Upstream Tx power of the CM: 40 dBmV
Upstream attenuation of the cable line: 20 dB
Fixed attenuation inside the CMC: 12 dB
NOTE
Use the MA5633 (D3.1, Cable Outlets on a Single Side) as an exmaple.
Rx power of the CMC DOCSIS module: 6 dB. Therefore, the upstream attenuation is 2
dB (40 - 20 - 6 - 12)
Upstream signal slope of the frequency mixing board: 2 dB.
Configure the Tx power of 32 DOCSIS 3.0 channels.
huawei(config-if-cable-1/1/0)#cable downstream 1 frequency 109 channel-mode
docsis annex AnnexB rf-power 32
NOTE
This configuration method is similar to other DOCSIS 3.0 channels.
Configure the Tx power of 32 EQAM channels.
huawei(config-if-cable-1/1/0)#cable eqam-channel 33 frequency 302 rf-power 32
NOTE
This configuration method is similar to other EQAM channels.
Configure the Tx power of the OFDM DOCSIS 3.1 channel.
huawei(config-if-cable-1/1/0)#cable ofdm-downstream 97 lower-frequency
800000000
upper-frequency 992000000 rf-power 36
Set the downstream RF power adjustment to auto.
huawei(config)#cable rf-power 0 downstream adjust-mode auto
Configure the expected Tx power of an RF port.
huawei(config)#cable rf-power 0 downstream group 1 max-frequency 1218 type
catv-qam rf-out-power 50 rf-out-equalizer 18
huawei(config)#cable rf-power 0 downstream group 2 max-frequency 1218 type
catv-qam rf-out-power 50 rf-out-equalizer 18
Configure the power difference between digital CATV signals and DOCSIS 3.0 signals.
huawei(config)#cable rf-power 0 downstream adjust-mode auto catv-docsis-diff 4
Configure the downstream monitoring frequency.
huawei(config)#cable rf-power-monitor 0 downstream index 1 freq-width 8000
frequency 510 type catv-qam
huawei(config)#cable rf-power-monitor 0 downstream index 2 freq-width 6000
frequency 302 type doc-scqam
Configure the attenuation of the upstream RF port of the upstream combiner.
huawei(config)#cable rf-power 0 upstream group 1 attenuation 2 equalizer 2
huawei(config)#cable rf-power 0 upstream group 2 attenuation 2 equalizer 2
Copyright © Huawei Technologies Co., Ltd.
Type
Frequency
(MHz)
Digital CATV
510
signal
DOCSIS 3.0 and
302
EQAM signals
6 Configuring Intelligent RF Adjustment
Frequency Band
(kHz)
8000
6000
25