3.2. Machine installation
Protect the machine against humidity, rain and dust!
The machine may be operated in the ambient temperature between + 5° and + 40°C. The average air temperature must not exceed +
35°C within 24 hours. In temperatures below + 5°C the conventional coolants should be replaced by coolants designed for such
temperatures.
3.3. Connection to the mains
Make sure that the grid voltage, the voltage protection and the connection voltage comply with the power requirements specified in
the point 2. Technical parameters. Connect the power cable to a protected 16A socket, in case of direct connection to the mains it is
necessary to fit the supply with a lockable master switch. In machines with a 230V single-phase motor the 230V plug is installed.
When connecting V400 (with a three-phase 400V motor) machines to the mains (3 NPe, 50 Hz, 400 V, TN-S), mind the colour coding
of wires carefully: L1 brown, L2 black, L3 gray, N blue, PE yellow-brown. Improper connection of the neutral or PE wires may
lead to damage of the electrical equipment or to and electric shock! If the motor rotates in an incorrect direction, swap the
conductors L1 brown, L2 black on the junction box.
Failure to observe the aforementioned may lead to incorrect rotation of the bandsaw and the coolant pump.
Danger: Damage to the machine!
3.4. Nameplate
MANUFACTURER
MANUFACTURER'S ADRESS
MACHINE MODEL
SERIAL NUMBER
TOTAL WATTAGE
OPERATING VOLTAGE
Such operations must be carried out only by persons with electrician qualifications!
Pilous-pásové pily, spol. s r.o.
Producer
Železná 9, 619 00 Brno, CZ
Address
Model
Serial No.
P
U
The data are only illustrative
Year
YEAR OF MANUFACTURE
MACHINE WEIGHT
I
RATED CURRENT
CONTROL VOLTAGE