Bit definition of Control DI

With the communication function, reading the following objects enables reading of the on/off state of the input device. In
addition, the input device can be set to on/off by writing to the following objects.
• Control DI 1
Bit
Symbol
Description
0
The value at reading is undefined. Set "0" when writing.
1
2
3
4
C_CDP
Gain switching
5
C_CLD
Fully closed loop control switching
6
The value at reading is undefined. Set "0" when writing.
7
8
9
10
11
12
13
14
15
• Control DI 2
Bit
Symbol
Description
0
The value at reading is undefined. Set "0" when writing.
1
2
3
4
5
6
7
8
C_PC
Proportional control
9
The value at reading is undefined. Set "0" when writing.
10
11
12
13
14
15
C_ORST
Operation alarm reset
Reference
Refer to "SIGNALS AND
WIRING" in the following manual.
MR-J5 User's Manual
(Hardware)
Reference
Refer to "SIGNALS AND
WIRING" in the following manual.
MR-J5 User's Manual
(Hardware)
7 CiA 402 DRIVE PROFILE