  • Page 1 Information contained in this document is subject to change without notice. This User’s Manual can also be downloaded from EverFocus‘ Website (http://www.everfocus.com.tw Please go to the EN310 product page and then click the Download tab to download the User’s Manual.
  • Page 2 • the soft cloth with water or neutral detergent can be used. But the cloth should be tweaked sufficiently. WEEE Ihr EverFocus Produkt wurde entwickelt und Your EverFocus product is designed and hergestellt mit qualitativ hochwertigen Materialien manufactured with high quality materials and und Komponenten, die recycelt und wieder components which can be recycled and reused.
  • Page 3: Table Of Contents

    Content Introduction ..........................1 Package Contents ..........................1 Dimensions ............................1 Physical Description ........................2 General Operation ........................3 Battery Charging ..........................3 IP Camera Directly Connection ......................4 Analog / CVI / TVI / AHD Camera Connection ................... 4 General Screen Operation .........................
  • Page 4 4.3.5.11 PTZ Address Scan ....................39 4.3.5.12 Contact........................39 4.3.5.13 Lock Screen ......................39 4.3.5.14 TesterPlay ....................... 40 4.3.5.15 Factory Default ....................... 42 4.3.5.16 Power Off ........................ 42 4.3.6 Theme ............................. 43 4.3.6.1 Theme ........................43 4.3.6.2 Background ....................... 44 4.3.7 Quick Office ..........................
  • Page 5: Introduction

    EN310 4“ Touch Screen Test Monitor Introduction EverFocus’ EN310 4-inch test monitor comes with a touch panel and is designed for maintenance and installation of IP cameras, analog cameras, TVI, CVI AHD cameras, as well as testing 4K H.264 / 4K H.265 camera with mainstream.
  • Page 6: Physical Description

    EN310 4“ Touch Screen Test Monitor Physical Description No. Name Description When the device battery is being charged, the LED notification light will stay red. Charger LED When the battery is fully charged, the ligt will be off automatically. Please refer to 3.1 Battery Charging.
  • Page 7: General Operation

    EN310 4“ Touch Screen Test Monitor Left Right No. Name Description Insert an external micro SD card. The external micro SD card can be used to SD Card Slot backup files from the internal SD card. Up to 32GB micro SD card is supported.
  • Page 8: Ip Camera Directly Connection

    EN310 4“ Touch Screen Test Monitor IP Camera Directly Connection If your IP camera requires an independent power supply, connect the LAN cable of the IP camera to the LAN port of the device and then power up the IP camera with your power supply.
  • Page 9: General Screen Operation

    EN310 4“ Touch Screen Test Monitor Note: After connecting the camera to the Video Input port of the device, you will have to tap the following icon to get the camera streams. On the Main page, tap CVBS & HD Camera to enter this page.
  • Page 10: Dropdown Menu

    EN310 4“ Touch Screen Test Monitor To move icons to other Main Page folders: 1. On the Main Page, tap on an icon to enter a sub-menu. Tap the finger icon in the lower-right corner, the icon color will change from white to orange.
  • Page 11 EN310 4“ Touch Screen Test Monitor CVBS: Tap to enter the HD CVBS page. To close the page, tap the icon. LAN Info: Tap to display the network info window. To close the window, tap the icon. Power Output: Tap to turn on the PoE power output, a“PoE 48V ON”info will be displayed on the top-left of the screen.
  • Page 12: Screen Capture

    EN310 4“ Touch Screen Test Monitor 3.4.3 Screen Capture You can capture screen and save it to the internal SD card using the Enter key. To capture screen image: 1. Press and hold the Enter key on the top of the device, the screen image will be captured. By default, the captured screen images will be saved in the internal SD card (/sdcard/screenshots).
  • Page 13: Exporting Files To Pc

    EN310 4“ Touch Screen Test Monitor 3.4.4 Exporting Files to PC The files stored in the SD card, such as snapshot images, recordings, test reports and etc., can be exported to your PC. There are two ways to export files to PC: 1) Use external SD card 2) Use FTP server.
  • Page 14 EN310 4“ Touch Screen Test Monitor ii) Tap the Return button twice to find the extsd folder. iii) Tap extsd to enter the extsd folder and then tap the Paste button. The images will be pasted to the extsd folder.
  • Page 15 EN310 4“ Touch Screen Test Monitor 2. On your PC, open a folder and then type in the FTP server address (ftp://xxx.xxx.xxx.xxx:xxxx). Press the Enter key and then you should now access the internal/external SD card of the tester. 3. Now you can copy the files from the internal/external SD card to your PC. You can also create folder in...
  • Page 16: Main Page

    EN310 4“ Touch Screen Test Monitor Main Page After switching the Power Switch on and then press the Power key for 2 seconds, the Main Page appears. There are 5 folder icons on the Main Page, including IP Camera Test, CVBS & HD Camera, Tools, My APPS and More.
  • Page 17: Ip Discovery

    EN310 4“ Touch Screen Test Monitor To enable the PoE power output function: 1. Ensure the power of the tester is full or more than 80% charged, otherwise, the tester will show “low power” and “not able to supply power”.
  • Page 18: Onvif

    EN310 4“ Touch Screen Test Monitor PING Start: Tap to ping the searched IP cameras‘ IP address. ONVIF: Tap to enter the Rapid ONVIF Test page. Please refer to 4.1.3 ONVIF. IPC Test: Tap to enter the IP camera test page. Please refer to 4.1.4 IP Camera Test.
  • Page 19 EN310 4“ Touch Screen Test Monitor Auto Login: Tap to enable (Open) or disable (Close) the auto login function. By default, the ONVIF app will automatically login IP cameras with user name/password setup with admin/admin. If the login user name and password have been changed, the ONVIF app will use the modified user name and password to automatically login IP cameras.
  • Page 20 EN310 4“ Touch Screen Test Monitor Live Video: Tap to display live video streams. • You can also use the Live Toolbar on the lower side to operate multiple functions, including Photo, Snapshot, Manual Record, Audio, Video Player, PTZ and etc.. Please refer to Live Toolbar below for more details.
  • Page 21 EN310 4“ Touch Screen Test Monitor Photo: Tap to display the snapshot images.You can long tap on the image to delete or rename the image. Snapshot: Tap to take a snapshot of the current camera stream. The snapshot images will be automatically stored in the internal SD card (/sdcard/ONVIFToolPhoto/Photo) in png format.
  • Page 22: Ip Camera Test

    EN310 4“ Touch Screen Test Monitor Doc: Tap to generate the test reports (PDF) of the current camera. Tap Create documents and input some tester information. Optionally add snapshot images and then tap Create documents again, the PDF document will be saved to the internal SD card /sdcard/ONVIFToolDoc. To export the document to your own PC, please refer to 3.4.4 Exporting Files to PC.
  • Page 23 EN310 4“ Touch Screen Test Monitor IPC Camera IP: Enter the IP address of the IP camera manually. You can also tap Search to automatically search for the IP address. Note that it’s better to connect the IP camera to the tester directly so the search result will only display the camera’s IP address.
  • Page 24: Network Tool

    EN310 4“ Touch Screen Test Monitor Set: Tap to display the Photo and Video Storage window. • Photo Storage: Tap to automatically (Auto) or Manually (Manual) store the snapshot images to the internal SD card in png format. If Auto is selected, the snapshot images will be automatically stored to the internal SD card with a given file name.
  • Page 25: Scan

    EN310 4“ Touch Screen Test Monitor Note that if the IP cameras or network devices are not configured properly or not plugged in, the PING info will display “Destination Host Unreachable” or have 100% packet loss. On the contrary, if the IP cameras or network devices are connected properly, the sending and receiving packets will have 0% packet loss.
  • Page 26: Network Test

    EN310 4“ Touch Screen Test Monitor 4.1.5.3 Network Test Tap the Network Test icon to enter the page to test network bandwidth. There are two ways to test the network bandwidth: 1) using two testers or 2) using one tester and a computer.
  • Page 27: Port Flashing

    EN310 4“ Touch Screen Test Monitor 1. Prepare one tester and a computer. Connect the tester and computer on the same network with the same network segment. 2. Install a network bandwidth testing software in the computer, as a test Client or Server, to do the mutual testing with the tester.
  • Page 28: Dhcp

    EN310 4“ Touch Screen Test Monitor Use a network cable to connect between the tester and a network device (such as a switch). Tap the Port Flashing icon to enter the Port Flashing page. Tap the Start button, the tester will send a signal to the network device to make the LAN port flicker at a special frequency.
  • Page 29: Link Monitor

    EN310 4“ Touch Screen Test Monitor Tap the Trace Route icon to enter the Trace Route page. Input an IP address or a domain name in the Remote IP field. Set up a maximum hop count in the Hop TTL(ms) Address field (normally 30) and then tap the Start button.
  • Page 30: Hik

    EN310 4“ Touch Screen Test Monitor 4.1.6 HIK Tap IP Camera Test > HIK to enter the HIK test tool page. The HIK test tool page is designed for activating and debugging Hikvision IP camera. 1. If the connected IP camera is an unactivated Hikvision IP camera, the tester will automatically identify and display “Unactivate”in safety mode.
  • Page 31: Dh Test Tool

    EN310 4“ Touch Screen Test Monitor 4.1.7 DH Test Tool Tap IP Camera Test > DH Test Tool to enter the DH Test Tool page. You can use this page to install and debug the Dahua IP cameras. With this tool, you can display video streams, modify IP, user name and password, and etc..
  • Page 32: Cvbs & Hd Camera

    EN310 4“ Touch Screen Test Monitor CVBS & HD Camera Please note that since users can move the function icons from foders to folders, therefore, the functions described in the chapter are based on the default icon arrangement . 4.2.1 Analog / CVI / TVI / AHD Camera Test The way to test Analog , CVI, TVI and AHD cameras is the same.
  • Page 33 EN310 4“ Touch Screen Test Monitor 4. You can use the Toolbar on the right side of the screen. Playback: Tap to play back the snapshot images or the manual recordigs. You can long tap on a file to rename or delet it.
  • Page 34 EN310 4“ Touch Screen Test Monitor Call Position: Tap the left and right arrow buttons to select a preset number (1~128) and then tap Call Position to go to the preset position. • If UTC is selected, configure the below settings: Coaxitron: Tap the left and right arrow buttons to select between PTZ and Menu.
  • Page 35: Tools

    EN310 4“ Touch Screen Test Monitor Tools Please note that since users can move the function icons from foders to folders, therefore, the functions described in the chapter are based on the default icon arrangement . 4.3.1 DroiNotes You can use the DroiNotes to take a note. Tap the DroiNotes icon to enter the DroiNotes page.
  • Page 36: Data Monitor

    EN310 4“ Touch Screen Test Monitor 4.3.2 Data Monitor The Data Monitor function can be used to check whether the RS-485 communication states of the video optical transmitter is normal. Engineers can then analyze the protocol and check the data through the code displayed on the screen.
  • Page 37: Flashlight

    EN310 4“ Touch Screen Test Monitor 4.3.3 Flashlight You can use this page to turn on or turn off the flashlight. You can also set up a timer for the flashlight. Tap the Flashlight icon to enter the Flashlight page. The flashlight will turn on.
  • Page 38: Calculator

    EN310 4“ Touch Screen Test Monitor 4.3.4 Calculator Tap the Calculator icon to enter the Calculator page. 4.3.5 Settings Tap the Settings icon to enter the tester’s setting page. 4.3.5.1 Language & Input Language & Input to enter the Language &...
  • Page 39: Date/Time

    EN310 4“ Touch Screen Test Monitor 4.3.5.2 Date/Time Date/Time to enter the Date/Time page to set up the date/time of the tester. 4.3.5.3 IP Settings IP Settings to enter the IP Settings page. You can set up a static IP, DHCP or PPPoE for the tester.
  • Page 40: Brightness

    EN310 4“ Touch Screen Test Monitor 4.3.5.5 Brightness Brightness to enter the Brightness page. You can ajust the screen brightness and set up a sleep mode timer. 4.3.5.6 Volume Volume enter Volume page to adjust the volume for the tester.
  • Page 41: Ftp Server

    EN310 4“ Touch Screen Test Monitor capture and etc. will be recorded to the internal SD card. If you want to backup the recordings, images or other files to the external SD card, you will have to copy and paste the files from the internal SD card to the external SD card.
  • Page 42: Version Information

    EN310 4“ Touch Screen Test Monitor Note that you can choose either to view the external or internal SD card folders. Please refer to 4.4.3.3 FTP for more details. 4.3.5.9 Version Information Version Information enter Version Information page. You can view all the apps‘ version information.
  • Page 43: Ptz Address Scan

    Analog / CVI / TVI / AHD Camera Test. 4.3.5.12 Contact Contact enter Contact page. You can find the contact iformation of EverFocus Technical Support team. 4.3.5.13 Lock Screen Lock Screen enter Lock Screen page. By default, the tester’s screen is unlock. You can select to lock the screen by password or pattern lock.
  • Page 44: Testerplay

    EN310 4“ Touch Screen Test Monitor No Security: Select to unlock screen all the time. Password Lock Screen: Select to set up a password to unlock the screen. You can set up numeric, alphabetic, or special characters. Input the password again to confirm.
  • Page 45 EN310 4“ Touch Screen Test Monitor On the iPad, ensure to install an RTSP-supported App, such as VLC, in order to open the RTSP URL of the tester. Tap the Camera App to scan the QR code. When the QR code has been scanned, the iPad will pop-up a notification on the top window.
  • Page 46: Factory Default

    EN310 4“ Touch Screen Test Monitor 6. You should now see the mirroring screen on your iPad. 4.3.5.15 Factory Default Factory Default enter Factory Default page. Tap the Factory Default button to restore the tester to the factory default settings. All the personal files and apps will be removed.
  • Page 47: Theme

    EN310 4“ Touch Screen Test Monitor 4.3.6 Theme Tap the Theme icon to enter the Theme page. 4.3.6.1 Theme Tap the Theme tab on the left-side menu to enter the Theme page. You can change the app icon backgournd on this page.
  • Page 48: Background

    EN310 4“ Touch Screen Test Monitor 4.3.6.2 Background Tap the Background tab on the left-side menu to enter the Background page. You can choose whether to apply a Color or a Picture to the desktop/application. Tap the Color button and select a color, tap the Set button and select whether to apply the backgound to the desktop, application or both.
  • Page 49: Quick Office

    EN310 4“ Touch Screen Test Monitor 4.3.7 Quick Office Tap the Quick Office icon to enter the Quick Office page. The Quick Office supports excel, word and powerpoint file formats.
  • Page 50: My Apps

    EN310 4“ Touch Screen Test Monitor My APPS Please note that since users can move the function icons from foders to folders, therefore, the functions described in the chapter are based on the default icon arrangement . 4.4.1 Manual Tap My APPS > Manual to enter the manual page.
  • Page 51: Creating A Directory In Sd Card

    EN310 4“ Touch Screen Test Monitor Online Updates: Connect the tester to the internet to update the apps. Tap Online Updates to check the updates on the internet. If there are applications required to be updated, the applications will be listed on the page.
  • Page 52: Importing Files To The Sd Card

    EN310 4“ Touch Screen Test Monitor B. Using a PC through FTP Server: Turn on the FTP Server and then use your PC to access the internal SD card of the tester. Create a folder in the internal SD card. Note that to have the write permission, you have to enable the I need to use FTP client function for the FTP server.
  • Page 53: File

    EN310 4“ Touch Screen Test Monitor 4.4.3.2 File Tap the File tab to enter the File page. You can enter each folder to play back recordings, view images and files or play audio files. 4.4.3.3 FTP Tap the tab to enter the page.
  • Page 54: Rapid Video

    EN310 4“ Touch Screen Test Monitor Internal SD: Select for users to access only the internal SD card. Start Service: Tap the button and the FTP server address will display. On your PC, open a folder and then type in the FTP server address. Press the Enter key and then you should now access the internal/external SD card of the tester.
  • Page 55: Rapid Ip Discovery

    EN310 4“ Touch Screen Test Monitor 4.4.5 Rapid IP Discovery Connect a network cable to the LAN port on the tester and then tap My APPS > Rapid IP Discovery to enter the Rapid IP Discovery page. Tap the Start button to search for all IP devices in the whole network segments.
  • Page 56: Mobilefocus

    EverFocus MobileFocus app. You can use MobileFocus app to access EverFocus’ DVRs, NVRs and IP Cameras. For more details about MobileFocus, please refer to the User’s Manual of MobileFocus. You can download the MobileFocus manual from EverFocus’ Website (Enter the Download page and download the MobileFocus_Android_UM.
  • Page 57: Audio Recorder

    EN310 4“ Touch Screen Test Monitor 4.5.1 Audio Recorder Use the supplied Audio Cable to connect an audio input device to the Audio Input port on the tester. Audio In Go to More > Audio Recorder to enter the Audio Recorder page. Tap the Record button to start audio recording in mp3 format.
  • Page 58: Video Player

    EN310 4“ Touch Screen Test Monitor 4.5.3 Video Player You can use this page to play back photos and video files. Go to More > Video Player to enter the Video Player page. Tap Photo Browser to view photos or tap Video Player to play back video files stored in theinternal SD card.
  • Page 59: Rtsp Player

    EN310 4“ Touch Screen Test Monitor 4.5.4 RTSP Player The RTSP Player can be used to view the RTSP video streams from IP cameras. If you are unable to view the IP camera via ONVIF or IP Camera Test function, you can try RTSP Player to view IP Camera through RTSP for IP camera testing.
  • Page 60: Specifications

    EN310 4“ Touch Screen Test Monitor Specifications Model EN310 Display 4“ touch screen camera tester with 800x480 resolution Network Port 10/100/1000M auto adjust, RJ45 H.265 Main Stream Test 4K H.265/H.264 camera image display with mainstream IP Discovery Auto-scan the cameras‘ IP under the same network segment...
  • Page 61 TEL: +1 626 844 8888 FAX: +1 626 844 8838 www.everfocus.com sales@everfocus.com Ihr EverFocus Produkt wurde Your EverFocus product is designed entwickelt und hergestellt mit and manufactured with high quality qualitativ hochwertigen Materialien materials and components which can und Komponenten, die recycelt und be recycled and reused.