Electrostatic discharge information

An electrostatic discharge (ESD) can damage static-sensitive devices or microcircuitry. Proper
packaging and grounding techniques are necessary precautions to prevent damage. To prevent
electrostatic damage, observe the following precautions:
Transport products in static-safe containers such as conductive tubes, bags, or boxes.
Keep electrostatic-sensitive parts in their containers until they arrive at static-free stations.
Cover workstations with approved static-dissipating material. Use a wrist strap connected to the
work surface, and properly grounded (earthed) tools and equipment.
Keep work area free of nonconductive materials, such as ordinary plastic assembly aids and
foam packing.
Make sure that you are always properly grounded (earthed) when touching a static-sensitive
component or assembly.
Avoid touching pins, leads, or circuitry.
Always place drives with the Printed Circuit Board (PCB) assembly-side down.
Use conductive field service tools.

Pre-installation procedure

Perform the steps below before you open the server or before you remove or replace any component.
Perform data backup.
1.
Turn off the server and all the peripherals connected to it.
2.
Unplug all cables from the power outlets to avoid exposure to high energy levels that may cause
3.
burns when parts are short circuited by metal objects such as tools or jewelry.
If necessary, label each cable to expedite reassembly.
Disconnect all telecommunication cables to avoid exposure to shock hazard from ringing
4.
voltages.
Open the server according to the instructions described in the "System covers" section later in
5.
this chapter.
Follow the ESD precautions listed previously in this chapter when handling any hardware
6.
component.
IMPORTANT:
procedure first and make sure you understand it before you begin.
To streamline the configuration process, read through the entire installation/removal