Removal And Replacement Procedures; Hardware Configuration Tools; Hardware Configuration Information; Electrostatic Discharge Information - HP ProLiant SL390s G7 4U Maintenance And Service Manual

Half-width server
Hide thumbs Also See for ProLiant SL390s G7 4U:
Table of Contents

Advertisement

Removal and replacement procedures

This chapter provides subassembly/module-level removal and replacement procedures for the HP
ProLiant SL390s G7 4U Half-width Server.
Review the specifications of a new component before installing it to make sure it is compatible with
the server. When you integrate new components into the system, record its model and serial number,
and any other pertinent information for future reference. After completing any removal or replacement
procedure, run the diagnostics program to verify that all components operate properly.
NOTE: The figures used in this chapter to illustrate procedural steps are labeled numerically (i.e., 1,
2...). When these figures are used in substep items, the alphabetically labeled instructions
correspond to the numbered labels on the related figure (i.e., label 1 corresponds to step a, label 2
corresponds to step b, etc.). The procedures described in this section assume that the server is out of
the rack and is positioned on a flat, stable surface.

Hardware configuration tools

You need the following items for some procedures:
T-10/T-15 wrench
Flat-blade screwdriver
Phillips screwdriver
The following references and software tools may also be used:
HP ProLiant SL390s G7 4U Half-width Server Easy Set-up CD
IPMI Event Log
Diagnostics Software

Hardware configuration information

Electrostatic discharge information

An electrostatic discharge (ESD) can damage static-sensitive devices or microcircuit. Proper
packaging and grounding techniques are necessary precautions to prevent damage. To prevent
electrostatic damage, observe the following precautions:
Transport products in static-safe containers such as conductive tubes, bags, or boxes.
Keep electrostatic-sensitive parts in their containers until they arrive at static-free stations.
Cover workstations with approved static-dissipating material. Use a wrist strap connected to the
work surface, and properly grounded (earthed) tools and equipment.
Keep work area free of nonconductive materials, such as ordinary plastic assembly aids and
foam packing.
Make sure that you are always properly grounded (earthed) when touching a static-sensitive
component or assembly.
Avoid touching pins, leads, or circuitry.
Always place drives with the Printed Circuit Board (PCB) assembly-side down.