HANDLING AUTO-GREASING SYSTEM
9. Adjustment of greasing rate and injector
q Adjust the injector to change the greasing rate for 0 - 30 hours (First step), 30 - 150 hours ((Second step)
and after 150 hours after the auto-greasing system installed.
q Set the interval to 11.25 minutes.
Interval
Injector
Greasing point
Bucket hinge
SL-11
(1)
(Right and left)
(2) Front bucket link
(3) Rear bucket link
(4) Bucket cylinder rod
Bucket cylinder
(5)
bottom
(6) Bell crank center
Boom cylinder rod
(7)
(Right and left)
Boom cylinder bot-
(8)
tom
(Right and left)
Boom pivot
(9)
(Right and left)
Center hinge pin
(10)
SL-1
(Upper)
Steering cylinder
(11)
bottom
(Right and left)
(12) Center support
Center hinge pin
(13)
(Lower)
Rear axle support
(14)
(Front)
Transmission
(15)
mount support
Rear axle support
(16)
(Cover)
Rear axle support
(17)
(Top)
Steering cylinder
(18)
rod (Right and left)
The injector turns by 10 turns between the full minimum opening positions.
6-8
Up to 30Hr
First step
11.25 min
Adjustment of
cc/Hr
injector
49.2
Open fully
15.6
Open fully
15.6
Open fully
7.8
Open fully
7.8
Open fully
15.6
Open fully
7.8
Open fully
7.8
Open fully
15.6
Open fully
7.8
Open fully
7.8
Open fully
7.8
Open fully
7.8
Open fully
15.6
Open fully
7.8
Open fully
15.6
Open fully
15.6
Open fully
7.8
Open fully
ATTACHMENTS, OPTIONS
Up to 150Hr
Second step
11.25 min
cc/Hr Adjustment of injector cc/Hr
Keep at position for
49.2
first step.
Open one fully. Close
7.8
one to minimum.
Keep at position for
15.6
first step.
Close by 5 turns from
3.9
full.
Close by 5 turns from
3.9
full.
Open one fully. Close
7.8
one to minimum.
Close by 5 turns from
3.9
full.
Close by 5 turns from
3.9
full.
Keep at position for
15.6
first step.
Close by 5 turns from
3.9
full.
Close by 5 turns from
3.9
full.
Close by 5 turns from
3.9
full.
Close by 5 turns from
3.9
full.
Open one fully. Close
7.8
one to minimum.
Close by 5 turns from
3.9
full.
Open one fully. Close
7.8
one to minimum.
Open one fully. Close
7.8
one to minimum.
Close by 5 turns from
3.9
full.
After 150Hr
Third step
11.25 min
Adjustment of injector
Keep at position for sec-
49.2
ond step.
Close one by 5 turns
3.9
from full. Close one to
minimum.
Keep at position for sec-
15.6
ond step.
Close by 2.5 turns from
1.95
position for second step.
Close by 2.5 turns from
1.95
position for second step.
Close one by 5 turns
3.9
from full. Close one to
minimum.
Keep at position for sec-
3.9
ond step.
Keep at position for sec-
3.9
ond step.
Keep at position for sec-
15.6
ond step.
Close by 2.5 turns from
1.95
position for second step.
Close by 2.5 turns from
1.95
position for second step.
Close by 2.5 turns from
1.95
position for second step.
Close by 2.5 turns from
1.95
position for second step.
Close one by 5 turns
3.9
from full. Close one to
minimum.
Close by 3 turns from
1.56
position for second step.
Close one by 5 turns
3.9
from full. Close one to
minimum.
Close one by 5 turns
3.9
from full. Close one to
minimum.
Close by 2.5 turns from
1.95
position for second step.
Need help?