Vallox DIGIT2 SE Series Manual

Vallox DIGIT2 SE Series Manual

Electronic controller with lcd display liquid radiator model electric radiator model

Advertisement

Quick Links

DIGIT2 SE MLV R
(liquid radiator model)
• Supply and extract air ventilation
with heat recovery
• Silent operation
• Energy-efficient unit; high-efficiency
cross-flow cell
• Electronic DIGIT SED control or
wireless remote monitoring (option)
• Week clock control
• Humidity control (option)
• Carbon dioxide control (option)
• Maintenance reminder
• Summer/winter automation
• Fireplace/booster switch function
• Good filtering
• Fixed air flow measuring outlets
• MLV model especially designed for
use with ground heat systems
• Easy and quick installation
© VALLOX • We reserve the right to make changes without prior notification.
Vallox
Digit
2
DIGIT
SED
ELECTRONIC CONTROLLER
WITH LCD DISPLAY
Models:
DIGIT2 SE R
DIGIT2 SE L
DIGIT2 SE VKL R
DIGIT2 SE VKL L
DIGIT2 SE MLV R
DIGIT2 SE MLV L
Electrical connection
Class of protection
Fans
Extract air 210 kW 0.91 A (AC)
Supply air 210 W, 0.91 A (AC)
Heat recovery
VALLOX DIGIT2 SE
Preheating unit
Post-heating unit
VALLOX DIGIT2 SE VKL
Preheating unit
Post-heating unit
VALLOX DIGIT2 SE MLV
Preheating unit
Post-heating unit
Filters
Supply air
Extract air
Weight
Ventilation
adjustment options
Options
SE
DIGIT2 SE R
(electric radiator model)
230 V, 50 Hz
IP34
120 dm
3
/s (120 Pa)
3
110 dm
/s (100 Pa)
Cross-flow cell, > 60%
2.7 kW, 12.0 A
Electric 1200 W, 5.2 A
Electric 1200 W, 5.2 A
1.55 kW, 6.7 A
Electric 1200 W, 5.2 A
VKL water radiator
0.35 kW, 1.5 A
MLV liquid radiator
VKL water radiator
G3 and F7
G3
71 kg
Control panel control
Week-clock control
CO
and %RH control (option)
2
Wireless remote control (option)
CO
sensor
2
%RH sensor
Wireless remote control
Filter guard (supply and/or extract air)
LON converter
Ceiling mounting
Attic floor penetration
• 1.09.391E
• 5.2.2009
• Code 3550 SE
© VALLOX

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DIGIT2 SE Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Vallox DIGIT2 SE Series

  • Page 1 • Easy and quick installation Wireless remote control (option) Options sensor %RH sensor Wireless remote control Filter guard (supply and/or extract air) LON converter Ceiling mounting Attic floor penetration © VALLOX • We reserve the right to make changes without prior notification.
  • Page 2 Supply air to the dwelling Outdoor and extract air prefilter G3 Connection ø 12 Summer/winter damper Supply liquid/water MLV connection ø 10 cu Return liquid/water Maintenance switch 10 10 © VALLOX • We reserve the right to make changes without prior notification.
  • Page 3 Observe unit model and dm 3 / s setting (summer or winter). Volume m 3 / h flow rate © VALLOX • We reserve the right to make changes without prior notification.
  • Page 4 (10 m sound absorption) ADJUSTMENT POSITION / AIR FLOWS (supply / extract) 44/48 l/s 55/62 l/s 76/81 l/s 93/105 l/s , dB(A) © VALLOX • We reserve the right to make changes without prior notification.
  • Page 5: Control Panel

    VALLOX DIGIT SED CONTROL PANEL Control VALLOX DIGIT SE can be controlled with the control panel coming with the unit (3 at most) and with optional CO (5 at most) and %RH sensors (2 at most). Fan speeds of the unit can be controlled via remote monitoring with a voltage or current signal.
  • Page 6: Humidity Sensors

    SLAVE UNIT TERMINAL BLOCK connected to a slave unit. NOTE! + wire must not be connected to a SLAVE UNIT. SLAVE UNIT must not have a 6K8 resistor in place. © VALLOX • We reserve the right to make changes without prior notification.
  • Page 7: Connection Box

    A FAN CONTROL USE OF JUMPER IN VOLTAGE USE OF JUMPER IN CURRENT WITH VOLTAGE/CURRENT SIGNAL SIGNAL CONTROL SIGNAL CONTROL SELECTION WITH JUMPER A (FACTORY SETTING) © VALLOX • We reserve the right to make changes without prior notification.
  • Page 8: Circulation Pump

    16 A WHEN THE UNIT IS EQUIPPED WITH ELECTRIC PRE- AND POST-HEATING 1.8 m FROM THE TOP OF THE UNIT SOLENOID VALVE CIRCULATION PUMP CONTROL OF EXTERNAL SOLENOID VALVE AND CIRCULATION PUMP IN MLV UNIT © VALLOX • We reserve the right to make changes without prior notification.
  • Page 9 Cooling of water in the radiator °C Liquid flow dm Temperature of air coming to the radiator 12 °C liquid flow 0.05 dm liquid flow 0.03 dm © VALLOX • We reserve the right to make changes without prior notification.
  • Page 10 50 dm 30 dm 70 dm 90 dm Geothermal liquid temperature °C Geothermal liquid temperature °C MLV RADIATOR PRESSURE LOSS 0.06 0.02 0.04 0.08 liquid flow, dm © VALLOX • We reserve the right to make changes without prior notification.
  • Page 11 Automatic/Adjustment range 1…99% (99) Option Selectable as either a fireplace or Separate switch Option Humidity control Adjustment interval 1...15 min. (10) booster switch function LON converter Remote monitoring control Option © VALLOX • We reserve the right to make changes without prior notification.
  • Page 12 TE4, aiming at keeping extract air temperature at the temperature value set on control panel H (+10…+30 ºC). © VALLOX • We reserve the right to make changes without prior notification.
  • Page 13 Damper 2 pcs Air flow operated Standard Humidity sensor Automatic/Adjustment range 1...99% (99) Option LON converter Remote monitoring control Option Humidity control Adjustment range 1...15 min. (10) © VALLOX • We reserve the right to make changes without prior notification.
  • Page 14 LON remote monitoring control Heat recovery bypass can be implemented with a VALLOX LON converter. (See a separate brochure.) Heat recovery is enabled whenever post-heating has been switched © VALLOX • We reserve the right to make changes without prior notification.
  • Page 15 Humidity sensor Automatic/Adjustment range 1...99% (99) Option Damper 2 pcs Air flow operated Standard Humidity control Adjustment interval 1…15 min. (10) LON converter Remote monitoring control Option © VALLOX • We reserve the right to make changes without prior notification.
  • Page 16 TE4, aiming at keeping extract air temperature at the temperature value set on control panel H (+10…+30ºC). © VALLOX • We reserve the right to make changes without prior notification.
  • Page 17: Ceiling Mounting

    CEILING MOUNTING VALLOX DIGIT2 SE can be equipped with an optional easy-to-use ceiling mounting plate (patent pending). The ceiling mounting plate is fixed to the ceiling with M8 thread bars. Fix the bars so that they stand the weight of the unit, i.e. approximately 71 kg.
  • Page 18: Installation/Wall Mounting

    17.5 17.5 Note! Distance between straight-line wing and wall is 2 mm. Wall mounting top bracket Wing Wall mounting bottom bracket © VALLOX • We reserve the right to make changes without prior notification.
  • Page 19: Pipe Connections

    Heat can be conducted to the post-heating radiator of DIGIT2 SE VKL in other ways than described above. It is possible to build a separate circuit for the radiator if higher power is desired, or the risk of freezing can be eliminated by using non-freezing heat transfer solution. For more information, see the instructions for VALLOX VKL connections.
  • Page 20 VALLOX DIGIT2 SE/VKL/MLV Vallox Oy • Myllykyläntie 9-11 • FI-32200 Loimaa • Tel +358-10 7732 200 • www.vallox.com © VALLOX • We reserve the right to make changes without prior notification.

This manual is also suitable for:

Digit2 se rDigit2 se lDigit2 se vkl rDigit2 se vkl lDigit2 se mlv rDigit2 se mlv l

Table of Contents