BP-LFP-1375
Limits for short-term, reversible errors
Abbreviation
Description
CUV
Cell undervoltage detection
COV
Cell overvoltage detection *
OCC1
Overcurrent detection during charging
OCC2
Overcurrent detection during charging
OCD1
Overcurrent detection during unloading 20.5 A for 6 s
OCD2
Overcurrent detection during unloading 21 A for 1 s
AOLD
Overload protection
ASCC
Short circuit detection during charging
ASCD
Short-circuit detection during unloading -66 A, 0µs. Reset after 5 s
OTC
Overtemperature detection of cells
during charging
OTD
Overtemperature detection of cells
during discharge
OTF
Overtemperature detection of MosFETs
UTC
Under temperature detection of cells
during charging
UTD
Undertemperature detection of cells
during discharge
Limits of prototype
2.2 V (Recovery 2.5 V)
3.8 V (Recovery 3.4
)
V
5.5 A for 5 s
6 A for 2 s
-66 A, 3 ms
110 A, 0µs
or 30 s
65 °C (Recovery 62 °C)
75 °C (Recovery 72 °C)
90 °C (Recovery 70 °C)
-30 °C (Recovery -27 °C)
-30 °C (Recovery -27 °C)