BP-LFP-1375

3. Technical data

BP-LFP-1375
Electrical data
Cell type
Nominal capacity
Nominal voltage
Energy
Voltage range Corepack
Overvoltage shut-off
Undervoltage shut-off
Undervoltage shut-off recovery
Undervoltage shut-off
(Shutdown mode)
Short-circuit shut-off
Fuse
Charging parameters
Charging-end-voltage
Recommended charging current
Shutdown by BMS
Operating temperature range
Shutdown temperature range
Discharge parameters
End-point voltage
Recommended discharge current
Shutdown by BMS
Operating temperature range
Shutdown temperature range
Mechanical data
Length
Width
Height
Weight
Storage
Recommended temperature range 25 °C ±5 °C
Recommended charge level
ANR26650M1-B
7.5 Ah
13.2 V
99 Wh
10 V – 14.4 V
Once first cell reaches 3.8V
Once first cell reaches 2.2 V
Single cell at 2.5 V
Single cell at 2.5 V after 255 s
66 A (< 1 µs)
25 A ATO
13.85 V
4 A
5 A (5.5 A for 5 s, 6 A for 2 s)
-20...+55 ° C
-30 °C (Recovery -27 °C) ... +55 °C (Recovery 62 °C)
8.8 V
11 A
20 A (20.5 A for 6 s, 21 A for 1 s)
-30 °C...+55 °C
-30 °C (Recovery -27 °C) ... +75 °C (Recovery 72 °C)
113 mm
66 mm
83 mm
980 g
80 %