Output Test Table Contd.
Number
63
64
65
NOTE: For output test numbers 66 through 71, select the level with the plus
and minus keys. The decimal point is displayed in the copy counter
when the component is ON, and the decimal point is off when the
component is OFF.
66
ON
ID Setting (1)
Lighter Copy
Auto
Image Density
Lighter Copy
Auto
Image Density
Lighter Copy
Auto
Image Density
Lighter Copy
Auto
Image Density
1 2 3 4 5 6
7 8
Lead Edge
Erase
4-23
Component
20 mm
Transfer Corona
15 mm
Trigger
10 mm
(T.Trig)
5 mm
20 mm
Separation Corona
15 mm
(AC)
10 mm
5 mm
20 mm
Separation Corona
15 mm
(DC)
10 mm
5 mm
20 mm
Development Bias (2)
Levels 0 to 9
15 mm
0 ...0 V
10 mm
1 ...--60 V
5 mm
2 ...--60 V
3 ...--80 V
4 ...--100 V
5 ...--120 V
6 ...--140 V
7 ...--160 V
8 ...--180 V
9 ...--200 V
6 January 1990