Ricoh FW 810 Service Manual page 102

Table of Contents

Advertisement

6 January 1990
3.2 INPUT TEST MODE
The input test mode allows you to check the current sensor status from the
operation panel.
3.2.1 Access Procedure
1. Turn OFF the main switch
2. Turn ON DIP101-6 and --8 on the main board.
3. Turn ON the main switch.
• •
The Call Service (
confirm that the correct mode has been selected.
4. Consult the following table, and select the image density level and lead
edge erase amount that are appropriate for the sensor you want to check.
• •
If the sensor is active, the Upper Exit Indicator will light. If it is not
active the Lower Exit Indicator will light.
3.2.2 Input Test Table
Number
ID Setting (1)
1
2
3
) and misfeed (
Lighter Copy
Auto
Image Density
Lighter Copy
Auto
Image Density
Lighter Copy
Auto
Image Density
ON
1
2
3
4
5
6
7
8
) indicators will blink. This is to
Lead Edge
Erase
20 mm
15 mm
10 mm
5 mm
20 mm
15 mm
10 mm
5 mm
20 mm
15 mm
10 mm
5 mm
4-14
Sensor
Original Set Detector
1st Original
Transport Detector
2nd Original
Transport Detector