4. Connect the supply hose (JJ) between the remote
fill station pump (AA) and fill coupler (FC) port
marked with an "I" (F
NOTICE
To prevent damage to the unit:
Check breather (J) vent for proper operation
before filling the tank (K).
Do not fill tank (K) beyond the overflow port (H).
Do not use the breather (J) as a port to fill the tank.
5. Start the remote fill station pump (AA).
6. When the tank (K) is filled:
The remote fill station pump (AA) stalls
(dead-heads),
the auto-fill shut off pin (v2) pops up as shown in
F
. 15,
IG
The pressure gauge needle rises to the fill
pump's set pressure.
Note: If the pump does not stall (dead-head) there is a
leak in the system.
F
. 15
IG
3A6941B
. 14).
IG
V2
7. Turn off the remote fill station pump (AA).
NO
8. Pull and hold the fill valve pressure relief knob (FF)
long enough to relieve line pressure between fill
valve (EE) and Auto-fill Shut Off Valve (V) and
between remote fill station pump (AA) and fill valve
(EE).
Note: The length of time it takes to vent the pressure
varies depending on the system design and installation.
In some installations it may be necessary to repeat Step
8 to ensure pressure is relieved.
9. Disconnect the supply hose (JJ) from the fill coupler
(FC) (F
. 14).
IG
10. Replace the dust cover (DC) over the fill coupler
(FC).