Graco SaniForce 3A5799E Instructions And Parts
Graco SaniForce 3A5799E Instructions And Parts

Graco SaniForce 3A5799E Instructions And Parts

12:1 sanitary pumps

Advertisement

Quick Links

Instructions and Parts
SaniForce™
SaniForce™ 12:1
SaniForce™
Specially designed
designed for
for use
Specially
Specially
designed
for
Important Safety
Important
Important
Safety Instructions
Safety
Read all warnings and instructions in this manual and in related
system manuals. Save
Maximum Working Air Pressure: 100
psi (0.7 MPa, 6.9 bar)
Maximum Working Fluid Pressure:
1450 psi (10.1 MPa, 100.4 bar)
12:1 Sanitary
12:1
Sanitary Pumps
Sanitary
use only
only in in in SaniForce
SaniForce drum
use
only
SaniForce
Instructions
Instructions
Save
Save all all all instructions.
instructions.
instructions.
PROVEN QUALITY. LEADING TECHNOLOGY.
Pumps
Pumps
drum or or or tote
tote unloader
unloader systems.
drum
tote
unloader
3A5799E
systems. For
For professional
professional use
systems.
For
professional
EN
use only.
only.
use
only.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SaniForce 3A5799E and is the answer not in the manual?

Questions and answers

Summary of Contents for Graco SaniForce 3A5799E

  • Page 1 Instructions and Parts SaniForce™ SaniForce™ SaniForce™ 12:1 12:1 Sanitary 12:1 Sanitary Pumps Sanitary Pumps Pumps 3A5799E Specially designed designed for for use use only only in in in SaniForce SaniForce drum drum or or or tote tote unloader unloader systems. systems.
  • Page 2: Table Of Contents

    Cleaning the Air Motor ........3 Performance chart ..........12 Priming Piston Lower Cleaning ......4 Disconnect the Pump ........4 Technical Data ........... 13 Disassemble the Pump......... 4 Graco Standard Warranty........14 Reassemble After Cleaning ......5 Reconnect the Pump........6 Models Models Models...
  • Page 3: Usage

    Usage Usage Usage Usage This procedure involves thoroughly disassembling and cleaning the individual parts in the pump lower. Prior to performing these procedures: This pump must be used as part of a SaniForce drum 1. Flush the pump and relieve pressure as or tote unloader system.
  • Page 4: Priming Piston Lower Cleaning

    Priming Piston Lower Cleaning Priming Piston Piston Lower Lower Cleaning Cleaning Priming Priming Piston Lower Cleaning Disconnect the the Pump Pump Disconnect Disconnect Pump 3. Remove the priming piston (121) and the valve plate (120). 1. Perform Cleaning Preparation, page 3 4.
  • Page 5: Reassemble After Cleaning

    Priming Piston Lower Cleaning 10. Remove the valve plate (108) and the piston 6. Install the bearings (110) and the u-cup seal (107). Remove the bearings (110) from the (109) on the piston (107). The lips of the piston piston. u-cup must face up.
  • Page 6: Reconnect The Pump

    18. Install the valve plate (120) and the priming piston Use a spanner wrench to tighten the coupling (121). Hand tighten the priming piston nut (122). nut securely. A Graco spanner wrench tool (p/n 112887) is available. 19. Hold the displacement rod (105) with a wrench.
  • Page 7: Parts

    Parts Parts Parts Parts Complete Pump Models 25N008 25N008C31 Apply PTFE tape to threads. Hand tighten only. Apply sanitary lubricant to ease assembly. Apply medium-strength (blue) thread locker. Apply an appropriate medium-strength thread locker on the nut (18) every time it is installed to prevent it from coming loose during operation.
  • Page 8 Parts Complete Pump Pump Model Model 25N008, 25N008, 25N008C31 25N008C31 Complete Complete Pump Model 25N008, 25N008C31 Description Description Description Qty. Qty. Qty. Ref. Ref. Ref. Part Part Part 24G787 MOTOR, SaniForce; 7.5 in; see manual 3A1211 DISPLACEMENT PUMP: 25N004 EN 10204, type 2.1 —...
  • Page 9: 25N004

    Priming Piston Displacement Pump Model 25N004 Priming Piston Piston Displacement Displacement Pump Pump Model Model 25N004 25N004 Priming Priming Piston Displacement Pump Model 25N004 3A5799E...
  • Page 10: Priming Piston Displacement Pump Model

    Kits Priming Piston Piston Displacement Displacement Pump Pump Model Model 25N004 25N004 Priming Priming Piston Displacement Pump Model 25N004 Ref. Part Description Description Description Qty. Qty. Qty. Ref. Part Description Description Description Qty. Qty. Qty. Ref. Ref. Part Part Ref. Ref.
  • Page 11: Product Dimensions

    Product Dimensions Product Dimensions Dimensions Product Product Dimensions Model Model Model A A A B B B C C C D D D in. (cm) in. (cm) in. (cm) in. (cm) 25D363 45.0 (114.3)* 20.6 (52.3)* 15.6 (39.6)* 6.5 (16.5) * Add 4.7 in.
  • Page 12: Performance Chart

    Performance chart Performance chart chart Performance Performance chart 3A5799E...
  • Page 13: Technical Data

    Technical Data Technical Data Data Technical Technical Data Maximum Fluid Working Pressure 1450 psi (10.1 MPa, 100.4 bar) Maximum Air Inlet Pressure 100 psi (0.7 MPa, 6.9 bar) Maximum Recommended Pump Speed 60 cycles/min, 8.5 gpm (32 liters/min) delivery Maximum size pumpable solids 1/4 in.
  • Page 14: Graco Standard Warranty

    Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations. This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts.

Table of Contents