Burst
The FY6800 can output a waveform with a specified number of cycles (called Burst)
from the CH1 channel. The FY6800 supports internal, manual or external trigger source
control of the pulse train output from CH2. The signal generator can generate pulse trains
using sine, square, sawtooth, pulse, noise, or arbitrary waves (except DC).

Turn on burst function

key, and then press the soft key corresponding to "Mode" to select
MOD
Press
"Trigger" mode to enter the burst output function. The instrument supports three trigger
output modes [CH2], [External], and [Manual], which can be selected with the
corresponding soft keys. Press the corresponding soft key of "Parameter" to set the
number of pulse train pulses. When the number of pulses is selected, use the arrow keys
and parameter adjustment knob to change the number of pulses output by a single burst.
The default is 1, The range is from 1 to 1048575. After parameter setting is completed,
the signal generator will output the burst waveform from the CH1 channel (if currently
open) according to the current trigger configuration.
Normal mode, burst off mode.
CH2 trigger mode, that is, CH2 has a pulse, then CH1 outputs a burst of burst
waveform.
External trigger mode, that is, there is a pulse input on the Trig.IN terminal, then CH1
outputs a burst of burst waveform.
Manual trigger mode, the user can press the [OK] button to trigger CH1 to output a
series of burst pulse waveforms.