RG165T-R Operator · Service · Maintenance
Maintenance
Cooling Screens
The RG165T-R is equipped with two removable cooler
screens that can be easily removed to keep the coolers
working at their maximum efficiency. One is located at the
rear of the machine at the engine radiator and the other is
on the cooler door on the right side of the machine.
1
To remove the screen from the engine radiator loosen the
wing nut (1) tensioning the red retainer (2) rotate retainer
away from the screen and pull screen (3) outward.
46
2
To remove the oil cooler screen, remove the two bolts (4)
using a 9/16 wrench, and swing open the cooler door.
Locate the screen and pull outward.
3
2
2