Maintenance
Fuel Tank - Drain
NOTICE
Dispose of any drained fuel according to local
environment protection regulations.
1. Clean the fittings and tank.
2. Place the machine on level ground.
3. Expand the tracks out.
4. Place a container on the ground under the fuel tank drain
plug (1). The drain plug is located below the fuel tank.
5. Remove the plug and fuel cap and allow the fuel to drain
into the container.
6. Replace and tighten the drain plug.
42
Hydraulic Oil - Check & Fill
The hydraulic oil tank (2) and fill neck (3) are located in the
front of the engine compartment just behind the cutter boom.
Check your hydraulic oil level daily before use. Check the oil
level only when the machine on level ground. The oil level
sight gauge (4) is located on the tank's rear face.
KEEP INSIDES OF ALL HYDRAULIC COMPONENTS
CLEAN AS THEY ARE INSTALLED.
ALWAYS KEEP THE HYDRAULIC OIL CLEAN.
1
SEVERE MACHINE DAMAGE WILL LIKELY OCCUR
THE MACHINE MUST NOT BE OPERATED WITHOUT
THE FILTER IN PLACE, OR SEVERE DAMAGE TO
THE MAJOR HYDRAULIC COMPONENTS WILL
IF OIL BECOMES DIRTY.
LIKELY OCCUR.