Page 1
Z-5252 Compact 2D Image Scan Module Service Guide Revision History Changes to the original manual are listed below: Version Date Description of Version March 11, 2014 Initial release...
All trademarks mentioned herein, registered or otherwise, are the properties of their various respective owners. This manual is in A4 format. Please check your printer setting before printing it out. Z-5252 Service Guide 2 / 9...
ERVICE UIDE Table of Contents Preface..................................2 Important Notice ..................................2 Table of Contents................................3 Scanner Parts ..................................4 Take Apart ..................................6 Before You Start ..............................6 Important Instructions ..............................6 Tools to Prepare ..................................6 Z-5252 Service Guide 3 / 9...
Follow all instructions. • Heed all warnings. Tools to Prepare • Philips screwdriver. Please follow these steps to take apart Z-5252. Remove the 4 screws from the case. Separate the top and bottom cases. Z-5252 Service Guide 6 / 9...
Page 7
ERVICE UIDE Remove the name plate from the top cover. Remove the screws circled in red. Remove the PCB fixture. Z-5252 Service Guide 7 / 9...
Page 8
ERVICE UIDE Lift the decoder board then remove the FFC cable and the FPC cable circled in red. Remove the decoder board. Remove the cables. Z-5252 Service Guide 8 / 9...
Page 9
Remove the screws from the main board and remove the main board. Remove the screws from the main board. Remove the 2D engine. Note: To assemble the device, please start from the last step and work your way backwards. Z-5252 Service Guide 9 / 9...