17 - Firmware Version

Perform reset or turn the unit OFF and then ON
The version number is displayed in the upper part of the screen.
The number displayed in the lower part of the screen is the scale type
Fig. 29 - Firmware version

18 - Operational hints and Trouble-shooting

When the Military ALTITRACK detects a fault, an error ("ERR") symbol and trouble shooting
numbers 2 to 5 and 100 are displayed in the upper part of the LCD screen. At the same time the
unit beeps every minute.
The "ERR" trouble shooting codes are as follows:
ERR 2 (both transducers are defective)
ERR 3 (both transducers are out of range)
ERR 4 (crystal defective)
ERR 5 (communication error to flash)
ERR 100 (flash defective).
Remedy: perform reset
If the unit still does not function correctly even after peforming reset and replacing the battery,
then perform following:
Press and hold
while resetting.
The Military ALTITRACK resets to factory settings and sounds three beeps.
If the unit is still faulty, please contact LARSEN & BRUSGAARD.