Installation Instructions MB-Secure 1000/2000/3000/4000/5000/6000
3.11

Special notes on installation and planning

Software version IDENT-KEY evaluation unit 023312.10 / door controller module for MB 023350
To operate a IDENT-KEY IK3 evaluation unit or a access control BUS-2 door module in conjunction with the
MB-Secure control panel, the evaluation unit or door controller module must compulsorily be at software version
V12 or higher.
Software versions for "Centralized Authorization " mode (number of IDENT-KEY ID data carriers >1024)
When "Centralized Authorization " mode is used, software version V13 or higher is mandatory for the BUS-2
user IDENT-KEY IK3 evaluation unit and Door controller module. BUS-2 user Doorguard must be configured
with software version V03.04 or higher.
Transmission devices
The transmission devices must be at
adjacent firmware versions.
Systems in VdS Class C must be operated with an integrated transmission device.
The transmission device must be located inside the control panel and installed with it.
Remote queries of the DSxx are not allowed according to VdS.
The connection between the control panel and the transmission device is made via the serial interface
or via relay. When using the DSxx, we recommend the serial interface. When using another
transmission device, the absence of feedback must be guaranteed. Additional relay assemblies may
have to be installed.
BUS-2 operating units
A maximum of 10 operating units can be connected to each BUS-2 Controller.
Firmware
In principle, the latest firmware for individual users in each case must be used so that all new functional
enhancements can be utilized. Firmware updates are device-dependent. You can find the relevant information
in the documentation of the respective device.
IB2 users
-
Up to 10 IB2 users per BUS branch
-
Maximum of 10 interface modules 013930 per control panel
-
Maximum of 40 I/O modules 013940 per control panel
Module / Parameter
IB2 branch
IB2 user
BUS-2 branch
BUS-2 user
013930 IB2 1to4 Bus expansion
TouchCenter Tuxedo (013002ff)
RF user
RF panic button
IB2 Bus expansion
When using the MB-Secure control
panel in combination with the IB2
bus expansion, the following
firmware versions are mandatory:
DS 6700 / DS 6750
DS 7700
max. per
MB-Secure
4
40
43
1200
10
50
256
32
MB-Secure
up to V04.07
from V04.08
from V07
from V09
max. per
BUS-2 branch
-
-
-
64
-
10
-
-
IB2 bus expansion
up to V01.12
from V01.14
31
max. per
IB2-branch
-
10
-
-
10
-
-
-