CDN ProAccurate INTP662 Manual

CDN ProAccurate INTP662 Manual

Infrared gun/thermocouple thermometer

Advertisement

Quick Links

for non-contact and internal temperatures
• NSF
Certified
®
• 1 & 3 second responses
• 1.5 mm thin tip
• 3.75" (9.53 cm) probe
• Infrared for non-contact surface temperatures
• Thermocouple probe for internal temperatures
• Dual function
• Maximum, minimum and lock modes for continuous
scanning
• 8-beam laser target illumination
• Distance:Spot = 8:1
• Data-hold
• One-button operation
• Backlit HACCP check lights
• Battery status indication
• Food-safe ABS plastic with BioCote
• Stainless steel probe
• Auto-off
• Battery and instructions included
Get Professional Results
Every Time!
Monitoring temperature is essential to keeping food safe.
The versatile INTP662 is a powerhouse kitchen tool.
Simply point the infrared gun toward the target and press
the trigger to get a quick reading of surface temperatures
or flip down the rapid-response thermocouple probe to
measure internal temperatures. Integrated HACCP check
backlighting instantly shows if temperatures are within
HACCP guidelines for safe food temperatures.
Minimum, Maximum and Lock
The INTP662 also offers Minimum, Maximum, and Lock
modes. Minimum mode displays the lowest temperature
among multiple targets. Maximum mode displays the
highest temperature among multiple targets. While Lock
mode continuously displays the temperature for up to
60 minutes. This is particularly useful for continuous
temperature monitoring.
Note: Remove sticker from display before use. Clean the
thermometer probe before each use.
Important: DO NOT LEAVE THERMOMETER IN HOT OVEN.
HAND WASH AND DRY. DO NOT IMMERSE HOUSING IN
LIQUID.
Thermocouple Thermometer
Note: In the following instructions, names of the control
buttons are shown in CAPS. Function information that
appears on the display is shown in BOLD CAPS.
®
Battery Installation
Replace battery when LCD becomes dim. Power off the
unit before installing the batteries. A malfunction may
occur if the power is on when the battery is installed. If a
malfunction occurs, restart the device.
ProAccurate
®
Infrared: -76 to +662°F/-60 to +350°C
Thermocouple: -76 to +662°F/-60 to +350°C
1. Remove battery cover by sliding it down along the
handle.
2. Install two 1.5V AAA batteries observing polarity
shown in compartment.
3. Replace the battery cover until it clicks shut.
Model: INTP662
Infrared Gun/

Advertisement

loading
Need help?

Need help?

Do you have a question about the ProAccurate INTP662 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for CDN ProAccurate INTP662

  • Page 1 Model: INTP662 ProAccurate Infrared Gun/ ® Thermocouple Thermometer Infrared: -76 to +662°F/-60 to +350°C Thermocouple: -76 to +662°F/-60 to +350°C for non-contact and internal temperatures Note: In the following instructions, names of the control buttons are shown in CAPS. Function information that • NSF Certified ® appears on the display is shown in BOLD CAPS. • 1 & 3 second responses • 1.5 mm thin tip • 3.75” (9.53 cm) probe • Infrared for non-contact surface temperatures • Thermocouple probe for internal temperatures • Dual function • Maximum, minimum and lock modes for continuous scanning • 8-beam laser target illumination • Distance:Spot = 8:1 • Data-hold • One-button operation • Backlit HACCP check lights • Battery status indication • Food-safe ABS plastic with BioCote ® Battery Installation • Stainless steel probe Replace battery when LCD becomes dim. Power off the • Auto-off...
  • Page 2 The infrared thermometer is supplied with a default defines the area of measure. Make sure the emissivity of 0.95, which standard for most uses. circle is smaller than the area being measured. The emissivity of the thermometer can be changed If the laser light circle is larger than the area from 0.10 (10E) to 1 (100E). Only experienced being measured, the reading will include ambient temperatures and make the reading inaccurate. personnel should attempt to make changes. For information relating to the emissivity of specific d. Measurement continues as long as the trigger materials, please contact CDN. is pressed. The newest reading updates the a. Press the trigger to turn the thermometer on. display. b. Press the MODE button five times to enter e. When the trigger is released, HOLD appears on Emissivity Mode. 95E flashes on the display. the display and the last reading remains visible c. Press the trigger to adjust the emissivity value for 15 seconds before the unit automatically in 0.01 (1E) increments. powers off. d. Press the MODE button again to exit 2.
  • Page 3 • The sensor lens is the most delicate part of the of one minute. thermometer and should be kept clean at all times. Take care when cleaning the lens. Use only a soft cloth 3.) Reinstall the battery (see Battery Installation). or cotton swab with water or rubbing alcohol. Allow the 4.) Press the Trigger to turn the thermometer on. lens to dry fully before using the thermometer. 5.) If the error message remains, please contact • Do not submerge any part of the thermometer in water. CDN for further assistance. Wipe clean with a damp cloth. C. Thermocouple Probe • Store the thermometer at room temperature between Important: The probe may be damaged if measurement -4 to +149°F/–20 to +65°C. temperature is lower than -76°F/-50°C OR higher than +662°F/+350°C. 1. Flip down the probe until fully extended. Precautions Important: Do not twist the probe or rotate it in wrong direction.
  • Page 4: Specifications

    Specifications USDA SAFE FOOD TEMPERATURES * Beef, Veal, Lamb – well ..160°F . . .71°C Thermocouple * Beef, Veal, Lamb – medium. 145°F . . 63°C Probe (K type, Grounded) Infrared Scan * Beef, Veal, Lamb – rare ..140°F . . 60°C -76 to +662°F/ -76 to +662°F/ Measurement Range -60 to +350°C -60 to +350°C Poultry ....165°F . . .74°C 32 to 122°F/0 to 50°C Operating Range * Pork/Ham – pre-cooked .
  • Page 5 The manufacturer and its affiliates reserve the right to make improvements or changes to this document and the products and services described at any time, without notice or obligation. 1-Year Limited Warranty: Any instrument that proves to be defective in material or workmanship within one year of original purchase will be repaired or replaced without charge upon receipt of the unit prepaid at: CDN, PO Box 10947, Portland, OR 97296-0947. This warranty does not cover damage in shipment or failure caused by tampering, obvious carelessness or abuse. For more detailed information on our products, please visit cdn-timeandtemp.com. © 04-2016 Component Design Northwest, Inc.