Download Print this page

Graco Fire-Ball A Series Instructions-Parts List Manual page 5

15:1 ratio spray system 2700 psi (186 bar) maximum working pressure
Hide thumbs Also See for Fire-Ball A Series:

Advertisement

General Information
NOTE: Reference numbers and letters in parentheses
in the text refer to the callouts in the figures and the
parts drawing.
NOTE: Always use Genuine Graco Parts and Acces-
sories, available from your Graco distributor.
Grounding
WARNING
FIRE AND EXPLOSION HAZARD
Before operating the pump, ground the
system as explained below. Also read
the section FIRE OR EXPLOSION HAZ-
ARD on page 4.
1. Pump: use a ground wire and clamp as shown in
Fig. 1. Loosen the grounding lug locknut (W) and
washer (X). Insert one end of a 12 ga (1.5 mm )
minimum ground wire (Y) into the slot in lug (Z)
and tighten the locknut securely. Connect the other
end of the wire to a true earth ground. Order part
number 222–011 Grounding Clamp and Wire.
2. Air and fluid hoses: use only electrically conductive
hoses.
3. Air compressor: follow manufacturer's recommen-
dations.
Installation
4. Spray gun or dispensing valve: ground through
connection to a properly grounded fluid hose and
pump.
5. Object being sprayed: follow your local code.
6. Fluid supply container: follow your local code.
7. Solvent pails used when flushing: follow your local
code. Use only metal pails, which are conductive,
placed on a grounded surface. Do not place the
pail on a nonconductive surface, such as paper or
cardboard, which interrupts the grounding continu-
ity.
8. T o maintain grounding continuity when flushing or
relieving pressure , hold a metal part of the spray
gun firmly to the side of a grounded metal pail,
then trigger the gun.
Fig. 1
Z
X
Y
W

Advertisement

loading

This manual is also suitable for:

Fire-ball 992-706 aFire-ball 992-714 a