Operation, Repair, Parts 313753G Fine Finish HVLP 7.0/9.0/9.5 - For portable spray applications of fine finish coatings. For professional use only.- 240 Vac Models: 257829, 257830, 257831 120 Vac Models: 257833, 257834, 257835 Maximum Working Pressure: 10 psi (0,07 MPa, 0.7 bar)
Warnings Warnings The following warnings are for the setup, use, grounding, maintenance and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risks. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applica- ble.
Page 4
Do not kink or over-bend the hose. • Do not expose the hose to temperatures or to pressures in excess of those specified by Graco. • Do not use the hose as a strength member to pull or lift the equipment.
Warnings Grounding and Electric Requirements This equipment requires a 240 Vac, 50 Hz, 15A circuit, Use 3-wire, 12 awg, 50 ft (15 m) or shorter, extension with a grounding receptacle. cords with ground prong. Do not alter the ground prong or use an adapter. Sprayer Components Table Sprayer Model...
Provides filtered air for spray ter and main) gun and motor R Storage tray Provides extra storage ™ Cleaning cup Provides storage for cleaning Graco EDGE spray gun G Spray gun holder ™ with EasyGlide trigger EDGE spray gun Provides external storage for...
Setup Setup Fluid Preparation Pressure Relief Procedure • Strain fluids before you spray. This includes color, reducers and hardeners. • Use a slower drying reducer or thinner to compen- sate for the faster drying time caused by the warm air The spray gun siphon cup is pressurized by the gun of the turbine.
Maintenance Maintenance The sprayer system is lifetime lubricated. The only main- • Tap filter gently on flat surface, dirty side down. tenance required is filter cleaning and replacement. • Direct, compressed air (100 psi(7 bar, 70 MPa) maximum) through filter panel in the opposite direction of arrows on side of filter (from the clean Filter Operation side to the dirty side.
Extension cord must be 3-wire, 12 AWG, 50 ft (15 m) or shorter. Hose too long Replace with shorter hose. See Graco Fine Finish Solutions brochure for hose part numbers. Circuit breaker trips Filter clogged Clean filter and replace as necessary High ambient temperature Move sprayer to cooler area.
Repair Repair Sprayer Disassembly 3. Place sprayer upside down. Remove four screws (77) from sprayer base plate (2). To avoid injury, including electric shock turn off sprayer and unplug power cord before performing any repair procedures on the turbine. 1. Remove four thumbscrews (18) and remove filter retainer (17), prefilter (20) and main filter (16).
Turbine Replacement Turbine Replacement Refer to Parts Drawing, page 14. 7. Install new gaskets (21, 23, 24, 59 and 60). Use min- eral spirits solvent (also called white spirit) to remove 1. Follow Sprayer Disassembly procedure, page 10. any adhesive remaining from old gaskets. 2.