Add Option 1EH (Improved Low Band Harmonics from 10 MHz to 3.2 GHz) Kit Part Number:
E8251-60382

Remove the Outer and Inner Signal Generator Covers

Remove the Outer Cover
Refer to
Figure
1.
1. Disconnect the power cord.
2. Using a T-20 driver, loosen the two screws (1) and remove the strap handle (2).
3. Using a T-15 driver, remove the center screws (3) on the four rear-panel feet (4).
4. Remove the four bottom feet (5) from the cover by lifting the tab and sliding the foot toward
the tab.
5. Place the signal generator on its side.
6. Tilt the signal generator forward and slide the outer cover (6) back to remove it from the frame.
Remove the Inner Top Cover
Refer to
Figure
2.
1. Using a T-10 driver, remove the screws (1) from the inner-top cover (2). There are twelve
screws for E8257D and eleven screws for E8267D.
2. Remove the inner-top cover.
6