Technical Specifications - Ei Electronics Ei600 Series Instructions Manual

Battery powered smoke & heat alarms
Hide thumbs Also See for Ei600 Series:
Table of Contents

Advertisement

It is important to check that all Alarms are communicating in their final installed
positions. If Alarms are rotated, have had their antennas extended and/or re-sited,
we would recommend that all the Alarms are returned to the factory settings and
then House Coded again in their final positions (see above). The RadioLINK +
interconnection should then be checked again by button testing all units.
(Note: The RadioLINK + module can be returned to the originally factory settings by
pressing and holding the House Code switch until the blue light flashes and then releasing.
This will take about 7 seconds. This clears the House Codes that have been learnt).

Technical Specifications

Supply Voltage:
RF Range:
RF Visual Indicator:
RF Frequency:
Max RF Power:
Dimensions:
Temperature Range:
Humidity Range:
Interconnect *:
3V internal lithium battery (non-replaceable)
A minimum of 100 metres in free space
Blue light flashes continuously for 0.5 to 3.5 seconds while
transmitting RF signal
868.499MHz (1% duty cycle)
+10dBm
57mm length x 30mm depth x 18mm height
0° to 40°C
15% to 95% Relative Humidity (non-condensing)
Up to 12 RadioLINK + or RadioLINK modules