Commissioning the Counter Modu/e
?
.
?
?
8. If necessary, setup yourinterrupt program inthe applicable
L
I
ON
It is expressly pointed out that incorrect handling or operating or incorrect connec-
tion can damage the 1P 281 module. This can also cause extensive damage to your
system. We make the assumption that only qualified personnel who are also
familiar with the ESD protection regulations will work with the module.
5 – 2
5. Switch off the programmable controller and insert the
module in the slot provided.
(Only certain slots are provided for interrupt processing
via interrupt lines.)
6. Setup the registers and write your startup
program in 06s 20 to 22
of your programmable controller.
your startup program. These registers supply
you with information concerning the module or
the individual counters.
7. Now setup your cyclic program in 061.
your program. These registers supply you
with information concerning the module or
the individual counters.
interrupt organization block.
9. When switching on the programmable controller, proceed
in the seauence as recommended below.
Switch on power voltage for the programmable controller.
(Perform an "overall reset" for the program memory if
switching on for the first time.)
3.
Transfer blocks from the programmer to the programmable
controller.
4.
Start the central processing unit with a "new start".
R 11192
Section 3.2 to
section 3.9