General Function Description
Type of plug connector: 15–way, sub D socket with screw lock The pin
Encoder inputs,
plug connectors
allocations of plug connectors X5 (for counter 1) and X7 (for counter 2)
X5 and X7
are identical.
5 V Encoder Signals in Accordance with RS 422
Pin
10
11
12
13
15
24 V Encoder Signals
1 Change the jumper so that the reference potential on pin 7 corresponds
to the-connected encoder (+ sections 1.4.1 and 2.3).
Pins 2 and 3 are not used.
1 – 8
15
9
Meaning
Designation
6
5.2 V
5.2 V encoder supply (option)
Reference potential of the module (S5 bus)
N
Zero marking pulse (N)
Zero marking pulse (~)
E
Counting signal (track B)
B
Counting signal (track B)
Counting signal (track Z)
A
Counting signal (track A)
Pin
Designation
Meaning
A*
1
Counting signal (24 V, track A*)
B*
4
Counting signal (24 v track B*)
5
24 V
24 V encoder supply
7'
Reference potential (24 ~
8
N*
Zero marking pulse (24 ~
9
RE
Load resistance for A*, B* and N*
8
0
1
R 11/92