Sensor Modules
SMC10
SMC20
SMC30
Additional system components
TM15
TM31
TM41
DC link components
Braking Module
Capacitor Module
Control Supply Module
Voltage Clamping Module
The sum of the losses of the various power components (Active Line Module, Smart Line
Module, Motor Module) is calculated from the power losses (following table) and electronic
losses (next table but one).
Overview, power loss, internal air cooling
Table 8-15
Active Line Modules
16 kW
36 kW
55 kW
80 kW
120 kW
Smart Line Modules
5 kW
10 kW
16 kW
36 kW
Single Motor Modules
3 A
5 A
9 A
18 A
30 A
45 A
60 A
85 A
Equipment Manual for Booksize Power Units
Equipment Manual, (GH2), 03/2006 Edition, 6SL3097-2AC00-0BP3
Unit
W
W
W
W
W
W
W
W
W
W
Overview of the power loss for components with internal air cooling
Unit
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
Cabinet Configuration and EMC Booksize
8.7 Information about cabinet cooling
Power loss
< 10
< 10
< 10
< 3
< 10
10
20
25
< 105
50
Power loss
260
630
900
1,350
2,200
89
170
165
370
30
55
80
165
290
430
590
750
8-39