Cabinet Configuration and EMC Booksize
8.4 Arrangement of components and devices
For components with a width of between 150 to 300 mm, the distance between the upper
and lower module row must be at least 500 mm.
Caution
Signal cables must not be routed parallel to power cables.
Wiring rules for DRIVE-CLiQ
See the Commissioning Manual.
Overview of the DC link supply adapter and DC link adapter
DC link supply adapter (cable outlet on top)
6SL3162-2BD00-0AAx
6SL3162-2BM00-0AAx
DC link adapter (cable outlet on side)
6SL3162-2BM01-0AAx
Note
The current carrying capacity of the DC link busbars must be taken into account. For the
specifications, see the technical specifications for the module.
8-16
Suitable for module width:
50 mm, 100 mm
150 mm, 200 mm, 300 mm
all
Max. connectable
cross-section
10 mm
2
95 mm
2
95 mm
2
Equipment Manual for Booksize Power Units
Equipment Manual, (GH2), 03/2006 Edition, 6SL3097-2AC00-0BP3
Max. current carrying
capacity
36 A
240 A
240 A