KVH Industries TracVision M7 Replacement Instructions Manual page 12

Main pcb
Hide thumbs Also See for TracVision M7:

Advertisement

TracVision M7
Main PCB Replacement Instructions
12
MCP (MultiSat Control Panel) Configuration
To flash the RF PCB, you need the special flash adapter cable supplied
with the MCP. This cable is available from KVH (KVH Part # 32-0807).
Figure 9 Flash Adapter Cable
Prepare the MCP
Before you can flash the RF PCB, you must prepare the MCP for
flashing.
Using the MCP buttons, perform the procedure shown in
Figure 10 Flashing Preparation
<Default Display>
Menu
Install Satellite?
Enter
Next
Select Next until "Operations
Mode?" is displayed.
Operations mode?
Yes
Next
Get antenna status?
Yes
Select Next until "Upgrade
software?" is displayed.
Return
Upgrade software?
Yes
^RF
Halt
Return
System Halted
Stereo Plug
DB9 Connector
Figure
10.
Next
Return
Return
Use Jack
Main^
Return

Advertisement