Download Print this page

KVH Industries TracVision M7 Replacement Instructions Manual page 11

Main pcb
Hide thumbs Also See for TracVision M7:

Advertisement

The procedure is complete! Be sure to return the old main PCB to
KVH.
NOTE: Before returning the main PCB, be sure to obtain an RMA number
from KVH Technical Support and write the number clearly on the outside of
the box. Shipments received without an RMA number will be returned to you
at your expense.
GyroTrac Configuration
To flash the RF PCB, you will need a special RF flash cable (KVH
Part # 32-0618-15). If you do not have a special RF flash cable, you can
make one from a DB9 male-to-female serial data cable. You will use
the three wires connected to the male end's following DB9 pins:
and 5.
a. Connect the DB9 end of the flash cable to your PC.
b. Connect the RF flash cable wires to the ADCU terminal,
as shown in
Figure
Figure 8 RF Port on Back of ADCU
58 (Pin #5)
59 (Pin #3)
60 (Pin #2)
60 59 58
60 59
58
57
56
Yellow Label
Green Label
1
2
3
4
5
6
c. Follow the Flash Update Wizard's onscreen
instructions to flash the RF board.
The procedure is complete! Be sure to return the old main PCB to
KVH.
NOTE: Before returning the main PCB, be sure to obtain an RMA number
from KVH Technical Support and write the number clearly on the outside of
the box. Shipments received without an RMA number will be returned to you
at your expense.
Main PCB Replacement Instructions
8.
48 47
46
45
44
43
42
41
40
39
38
37
55
54
53
52
51
50
49
Red Label
Blue Label
13 14
15
16
17
18
19
20
21
22
23
24
25 26
7
8
9
10
11
12
TracVision M7
2, 3,
ADCU
White Label
27
28
29
30
31
32
33
34
35
36
11