Download Print this page

Troubleshooting - Dometic ePower T Installation And Operating Manual

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

Troubleshooting

12
Troubleshooting
Fault
Cause
The control panel
Battery connected to eCore is flat.
does not come
eCore battery is disconnected or
on.
battery fuse (if present) is blown.
The starter does
Battery connected to eCore is flat.
not work when
The main switch is at "0".
ePower T start is
enabled (via
Starter shaft is dirty.
eCore).
Too much oil in the engine.
Power cable is disconnected or the
plug is removed.
eCore is damaged.
Starter is not receiving any power.
The starter turns
No LPG.
but the genera-
Spark plug is not receiving any power. ➤ Check the electric connec-
tor does not start.
Air intake is blocked.
eCore is damaged.
The generator
Too much oil in the engine.
tends to go off.
Load is over 1.8 kW.
Air intake is blocked.
eCore is damaged.
Choke is not available.
Air filter is dirty.
The generator is
eCore is damaged.
running but does
Choke is not available.
not supply any
voltage.
The throttle valve is blocked.
44
ePower T, ePower T LPG
Remedy
➤ Charge the battery.
➤ Check connection and fuses
between eCore and battery.
➤ Contact an authorised work-
shop.
➤ Charge the battery.
➤ Set the main switch to "1".
➤ Clean the starter shaft.
➤ Drain the oil.
➤ Check connection and fuses
between ePower T and
battery.
➤ Contact an authorised work-
shop.
➤ Replace or refill LPG bottle.
tions.
➤ Check the air filter (see chap-
ter "Servicing the air filter" on
page 42).
➤ Contact an authorised work-
shop.
➤ Drain the oil.
➤ Switch off loads.
➤ Check the air filter (see chap-
ter "Servicing the air filter" on
page 42).
➤ Contact an authorised work-
shop.
➤ Contact an authorised work-
shop.
EN

Advertisement

loading

This manual is also suitable for:

Epower t lpg