Replacing motor

For replacement parts, see Parts, page 38.
1.
Remove front panel, see Replacing front panel,
page 25.
2.
Remove tank cover, see Removing tank cover
page 26.
3.
Remove two wire spade connections and ground
wire from tank to motor.
4.
Turn tank over to access the motor.
309832D
5.
From bottom of tank, remove screws and washers
(23, 24, 25). Pull motor (34) from tank.
34
25
24
23
6.
Reassemble in reverse order.