3.2

Terminals

CM
X1
X2
X3
X4
X5
X6
X7
X8
CM
When the FR-A8AC is installed, STF, STR, RL, RM, RH, RT, CS, MRS of the inverter control terminal block are invalid and the
FR-A8AC input terminal (X1 to X8) is valid. (STF signal is assigned to X1 and STR signal to X2 only.)
Pr.
178
A8AC
is not
STF
STR
fitted.
Valid
terminal
A8AC
is
X1
X2
fitted.
For the details of Pr.178 to Pr. 189, refer to the Instruction Manual (Detailed) of the inverter.
Terminal symbol
X1, X2, X3, X4, X5, X6, X7, X8
CM
179
180
181
182
RL
RM
RH
X3
X4
X5
Description
120VAC Input signals
Common terminal to X1-X8
183
(184)
(185)
RT
(AU)
(JOG)
CS
X6
(AU)
(JOG)
X7
186
187
(188)
(189)
MRS
(STOP)
(RES)
X8
(STOP)
(RES)
CONTACT INPUT