6.3.17. Oil drainage engine
Remove the oil-level gauge. Remove the drain plug.
Assemble the drain plug ( with a new packing ring ).
Notice: The engine crankcase has on both sides a drain plug, which apply that:
under.
- Never try to remove oil along the backside.
This can end up in the nearby wiring and effect the machine harmful and even put is out of company.
At pollution an indication goes on at the control panel.
6.3.20. Battery
Check the battery on good connections / possible wear and whether the battery needs to be recharged. If
the idling battery voltage drops below: 12.6 V (or if stored / not used during 6 months), this must be re-
charged. This can happen by means of a trickle charger, standard charger or workhouse charger. Reloading
need to be done
Caution
electrical connection of the charger & the battery!