Scope Of Supply - BWT Multipur AP Series Installation And Operating Manual

Backwash filter
Table of Contents

Advertisement

Available languages

Available languages

Scope of supply

Scope of supply
Scope of supply
Scope of supply
Scope of supply
2 2 2 2 2
Backw
Bac
Bac
kwash filter Multipur AP
kw
kw
ash filter Multipur AP
ash filter Multipur AP, consisting of:
ash filter Multipur AP
Bac
Bac
kw
ash filter Multipur AP
1 1 1 1 1
filter
2 2 2 2 2 Electronic controller and backwashing device
3 3 3 3 3
with hydraulic drive
3 3 3 3 3 Transformer with plug
4 4 4 4 4
water outlet for pipe
water outlet for hose (dia. 20 mm)
5 5 5 5 5 manometer
5 5 5 5 5
Use
Use
Use
Use
Use
The Multipur backwash filters are used for filtration
of drinking and industrial water to protect the water
mains and the connected fittings, equipment,
machinery, tanks, boilers and production facilities
from malfunction and corrosion damage caused
by foreign particles.
The filters can also be used for filtration of well,
1 1 1 1 1
process, boiler feed, cooling and air conditioning
In these cases
In these cases
water. In these cases
In these cases
In these cases, advice m
from a specialist.
from a specialist.
from a specialist.
from a specialist.
from a specialist.
The filters are unsuitable for oils, greases, sol-
4 4 4 4 4
vents, soaps and other lubricating media. Water-
soluble substances also cannot be separated off.
Function
Function
Function
Function
Function
The untreated water flows through a stainless steel
filter element in the Multipur. Foreign particles >
100µm or > 200µm are thus retained. Depending
on their size and weight, these particles either fall
directly into the lower part of the filter housing, or
adhere to the filter element.
During backwashing, the seal at the rinsing water
outlet opens. The suction ring segments of the
backwashing element move from the bottom to
the top and back again over the entire filter surface
and thus clean the filter fabric by suction with clean
water at an extremely high flow rate.
Backwashing is carried out automatically at the
end of the set interval.
The pressure difference between the untreated
water inlet and the treated water outlet of the filter
is measured.
The backwashing process is triggered primarily
by differential pressure.
If heavy soiling of the filter element causes the
pressure difference to exceed the preset value
(approx. 0.8 bar) within the preset backwash in-
terval, the differential pressure generator causes
, advice m
, advice m
ust be obtained
ust be obtained
, advice must be obtained
, advice m
ust be obtained
ust be obtained
GB GB
GB GB
GB
11
11
11
11
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Multipur 80 aMultipur 65 a