Electronic superheat controller

Advertisement

Parameter
Injection
n04
Kp factor
control
n05
Tn seconds
n06
Td seconds
n09
Max SH
n10
Min SH
n11
MOP [bar] (max = off )
n15
Start time [sec]
n17
MinOdAtStart [%]
n18
Stability
n19
Kp min.
n20
Kp T0
n21
SH mode
1= MSS, 2 = Load app.
n22
SH close [K]
n44
TnT0 sec.
Service
---
AL/Light rel
---
Reset alarm
---
EKC State
Alarms
A34
A34 Battery low
---
Standby
---
EKC Error
---
S2 Error
---
S3 Error
---
Peinp. error
---
AI inp.error
---
No Rfg. Sel.
Read out
u06
Analog input [mA]
u10
DI1 status
u20
S2 temp. [°C]
u21
Superheat [K]
u22
Superheat Ref [K]
o03
Unit addr.
Appendix 1
1 = R12
7 = R13b1
2 = R22
8 = R23
3 = R134a 9 = R500
4 = R502
10 = R503
5 = R717
11 = R114
6 = R13
12 = R142b 18 = R402A

Installation considerations

Accidental damage, poor installation, or site conditions can give rice to malfunctions of the control system, and
lead to a plant breakdown. Every possible safeguard is incorporated into our products to prevent this. However, an
incorrect installation, for example, could still present problems. Electronic controls are no substitute for normal,
good engineering practice. Danfoss will not be responsible for any goods, or plant components, damaged as a result
of the above defects. It is the installers responsibility to check the installation thoroughly, and to fit the necessary
safety devices. Particular attention is drawn to the need for a "force closing" signal to controllers in the event of
compressor stoppage and to the signal requirement for suction line accumulators.
Your local Danfoss agent will be pleased to assist with further advice, etc.
DKRCC.PI.RR0.A3.02
PNU
3003
3004
3005
3015
3021
3013
3017
3012
3014
3024
3025
3026
3027
3039
2509
2046
2007
10035
20000
20001
20002
20003
20004
20005
20006
2504
2002
2537
2536
2535
2008
13 = User-defined 19 = R404A 25 = R290
14 = R32
20 = R407C 26 = R600
15 = R227
21 = R407A 27 = R600a
16 = R401
22 = R407B 28 = R744
17 = R507
23 = R410A 29 = R1270
24 = R170
R/W
Lock
Min.
R/W
-
0.5
R/W
-
30
R/W
-
0
R/W
-
1
R/W
-
1
R/W
-
0
R/W
-
1
R/W
-
0
R/W
-
0
R/W
-
0
R/W
-
0
R/W
-
1
R/W
-
1
R/W
-
10
R
-
0
R/W
-
0
R
-
0
R/W
-
0
R
-
0
R
-
0
R
-
0
R
-
0
R
-
0
R
-
0
R
-
0
R
-
0
R
-
0
R
-
-200
R
-
0
R
-
0
R/W
x
1
31 = R422A R36 = Opteon
32 = R413A
33 = R422D 37 = R407F
34 = 427A
35 = R438A 39 = R1234yf
30 = R417A
© Danfoss A/S (AC-MCI / sw), 2016-12
Actual
Max.
Default
value
20
20
2
120
600
120
0
90
0
100
100
10
60
100
6
200
200
20
0
90
0
0
100
0
5
10
5
3
1
0.3
4
10
0.4
1
2
1
40
15
4
30
120
30
0
1
0
0
1
0
0
100
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
30
0
0
1
0
0
200
0
0
100
0
0
100
0
240
240
240
41 = R449A
XP10
42 = R452A
38 = R1234ze
40 = R448A
Scale
*10
*1
*1
*10
*10
*10
*1
*1
*1
*10
*10
*1
*10
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*10
*1
*10
*10
*10
*1

Advertisement

loading