Surge Suppression - Lutron Electronics LL-INTMOUNT Integration Manual

Pir sensor
Table of Contents

Advertisement

Available languages

Available languages

Handling / ESD
Appropriate ESD protection should be taken when handling LL-INTMOUNT PCBs as the exposed PCB is
susceptible to ESD, which could damage the LL-INTMOUNT. The conformal coating on the PCB is meant to
protect it from moisture and is not intended as ESD protection.
Some safe places to hold the LL-INTMOUNT are the large blue varistor (lollipop), the relay, and the 5-pin
connector.

Surge Suppression

If the LL-INTMOUNT will be used in an environment that requires additional surge protection, such as outdoor
lighting, then it is up to the manufacturer of the luminaire to ensure that the additional surge protection is
provided. This is typically done with a separate surge protection device (SPD) rated for at least 10 kV.
Temperature / Humidity
The LL-INTMOUNT is designed to be installed inside a luminaire and therefore is designed to handle high
temperatures. The LL-INTMOUNT is designed and rated to operate in an ambient temperature of -40 – 176 ˚F
(-40 – 80 ˚C). Ambient air temperature is measured at least 1 in (25.5 mm) away from the LL-INTMOUNT.
The LL-INTMOUNT is not waterproof and should not be mounted in a location where it will receive direct contact
with water. It is, however, conformal coated and can withstand humid or moist conditions.
Regulatory Labelling Requirements
FCC
When integrating the LL-INTMOUNT into a product it must be ensured that the FCC labelling requirements are
met. This includes a clearly visible label on the outside of the finished product specifying the FCC identifier (FCC
ID: S4GEM35XB) as well as the FCC notice shown below. This exterior label can use wording such as "Contains
Transmitter Module FCC ID: S4GEM35XB" or "Contains FCC ID:S4GEM35XB" although any similar wording that
expresses the same meaning may be used. The label should also show the FCC Symbol as shown below.
FCC Notice: This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
FCC Symbol:
Industry Canada (IC-ID: 8735A-EM35XB)
The labelling requirements for Industry Canada are similar to those of the FCC. Again a clearly visibly label must
be placed on the outside of the finished product stating something like "Contains Transmitter Module,
IC: 8735A-EM35XB", although any similar wording that expresses the same meaning may be used.
Limelight by Lutron OEM Integration Guide
4
Customer Assistance: 1.844.LUTRON1
(1.844.588.7661)