LEVEL II PROGRAMMING

P Values
Level II program parameters can be adjusted to fine-tune
the conditioner's operation. The parameters are accessible
by pressing and holding the UP and DOWN buttons until the
control displays a "P" value.
The control must be in the home position to change
NOTE:
settings. See Table 3 for Level II parameters.
Typically the Level II parameters will not need to be adjusted
as the default settings accommodate most applications.
Contact your water treatment professional before attempting
any programming.
Table 2 Level II Parameters
Description
P9
Units of Measure
P10
Clock Mode
P11
Service Interval
Remote regeneration
P12
switch delay
Chlorine Generator
P13*
Options (not used on
"A" and "P" systems)
P14*
Refill Rate
P15
Draw Rate
Reserve Type
P16
(not used for
alternating mode)
Initial Average or Fixed
Reserve
P17
(not used for
alternating mode)
P18
Flow Sensor Select
K-Factor or
P19
Pulse Equivalent
Pr**
Refill First
Remote Switch
Pd
Operation
Notes:
(1) Default selected with valve type and resin volume.
(2) Factory Default is "0" for North America units and "1" for World units.
* Not used for 273 filter valves.
** Not used when the control is programmed for twin alternating systems.
Minimum
Range
Increments
0-1
1
0-3
1
0-250
1
3-250
1
0-2
1
1-700
1
1-700
1
0-3
1
0-70
1
0-7
1
1.00-99.99
0.01
0-9999
1
0-1
1
0-1
1
AUTOTROL
Default
Units
(2)
0 = US 1 = Metric
0 = 12 hour clock; flow rate service display
1 = 24 hour clock; flow rate service display
(2)
2 = 12 hour clock; Time of Day service display
3 = 24 hour clock; Time of Day service display
0
Months
Uses 30 days for each month; 0 = off
Time remote switch must be active to start
60
Seconds
regeneration.
0 = No chlorine generator
0
1 = Salt check only
2 = Generate chlorine
(1)
gpm x 100
(1)
gpm x 100
0 = Variable reserve delayed regeneration
1 = Fixed reserve delayed regeneration
0
2 = Variable reserve immediate regeneration
3 = Fixed reserve immediate regeneration
% of
30
Depends on value entered in P16
capacity
0 = Internal Magnum NHWB
1, 6 = 1" Autotrol turbine
2, 7 = 2" Autotrol turbine
3 = User defined K-factor
(1)
4 = User defined Pulse Equivalent
5 = Internal Magnum HWB
Values 6 & 7 are for single turbine
configurations on twin alternating systems
0.01
K-factor P18 = 3;
1
Pulse Equivalent P18 = 4
0 = Refill first off
0
1 = Refill first on
0 = Immediate Regeneration after P12 time
0
1 = Delayed Regeneration after P12 time
Logix 764 Control Performa Cv Series Valves (273, 278) Service Manual
®