ELECTRICAL (cont.)

ELECTRICAL CONNECTIONS

NOTE: Ensure that the power supply is appropriate
based on the control configuration ordered with the unit.
One electrical connection is required. To connect the
waste collection system to the electricity:
1
2
Remove top cover retainers by loosening screws and
open the front panel.
NOTE: Electrical disconnect switch must be in OFF
position to open control panel (see Figure 12).
2
1/2" Knockout
Run power from main power supply to the 1/2" knockout
on bottom of control and connect as shown.
NOTE: Be sure to use liquid tight conduit and conduit
fittings.
3
1
Close front panel and tighten screws on top cover
retainers to secure.
Installation Instructions
Control
Solenoid
(Pre-wired)
Pump
(Pre-wired)
Incoming
Power
(1/2" Conduit)

INITIAL SETUP AND VERIFICATION

PREPARE THE SYSTEM

1
Electrical
Disconnect
Switch
Turn electrical disconnect switch to the ON position.
Open shutoff valves in water lines, if installed.
2
Start
Press the START button. Indicator light turns on.
NOTE: If the unit does not turn on, see Troubleshooting.
3
Verify that the pump is functioning correctly.
IMPORTANT NOTE: Wait time until pump
engages is approximately 70 seconds after
starting unit.
9
ON
Position
Indicator Light