18.
The lighting tower will now run in the
AUTO MODE.
19.
The following machine conditions will
cause the lighting tower to shut-
down when running in AUTOMODE.
• Pushing the Emergency Stop button.
• Opening the trailer canopy.
• Pressing the STOP button on the
LED controller.
• Triggering of the following engine
alarm conditions;
a) low oil pressure
b) low water level
c) high temperature
d) low fuel level
20.
When the COUNTDOWN time has
elapsed all tower lights will be
switched-off in sequence.
21.
The controller will allow the engine
a 20 second cooling cycle before
initiating engine shut-down.
Section 1
METRO-LED
MACHINE CONTROLS
OPTIONAL METRO-LED MODULE
SETTING THE DATE & TIME
1. Press the MENU/CONFIRM button.
2. Scroll to '3 Time Calibration'.
3. Press MENU/CONFIRM to enter the
time calibration.
4. The SET MODULE DATE/TIME screen
display.
5. Use the UP /DOWN arrows to adjust
the values assigned to date/time.
Enter MENU/CONFIRM to advance to
the next field.
Note the date format is DD-MM-YY.
Page 1-12