  • Page 1 Oshkosh Corporation Classification ‐ Restricted  JLG LT Operation and Safety Manual Lighting Tower Models JLG LT 1001281353 July 28, 2022 1001281353 JLG Industries (Australia) Pty Ltd Page 1-1 Oshkosh Corporation 28JUL22...
  • Page 2 Oshkosh Corporation Classification ‐ Restricted  JLG LT 1001281353 JLG Industries (Australia) Pty Ltd Page 1-2 Oshkosh Corporation 28JUL22...
  • Page 3 NSW 2143 SA 5107 Phone: (02) 8718 6300 Phone: (08) 8259 8777 JLG Industries (New Zealand) 2b Fisher Crescent Mt Wellington, Auckland New Zealand Phone: + 64 9276 1728 1001281353 JLG Industries (Australia) Pty Ltd Page 1-3 Oshkosh Corporation 28JUL22...
  • Page 4: Table Of Contents

    OPERATION AND SAFETY MANUAL CONTENTS Page INTRODUCTION……………………………1-05 SAFETY ALERT SYMBOLS……………….1-06 SAFETY PRECAUTIONS………………….1-07 INSPECTION & PREPARATION..…….….1-09 MACHINE CONTROLS…………………….1-12 MACHINE OPERATION…….……………..1-14 LIFTING & TRANSPORTATION…...……..1-21 MACHINE STORAGE.……………………..1-22 MACHINE SPECIFICATION……………..1-24 LIGHTHEAD ISOLUX PLOTS……………..1-26 1001281353 JLG Industries (Australia) Pty Ltd Page 1-4 Oshkosh Corporation 28JUL22...
  • Page 5: Introduction

    If there is a question on application and/or operation, JLG Industries (Australia) Technical Services should be contacted on 131JLG. All instructions in this manual require the lighting tower to be operated in the conditions for which it was designed.
  • Page 6: Safety Alert Symbols

    INDICATES INFORMATION OR A COMPANY POLICY THAT RELATES DIRECTLY OR INDIRECTLY TO THE SAFETY TO THE SAFETY AND PROTECTION OF PERSONNEL AND PROPERTY. INDICATES PROCEDURES ESSENTIAL FOR SAFE OPERATION. 1001281353 JLG Industries (Australia) Pty Ltd Page 1-6 Oshkosh Corporation 28JUL22...
  • Page 7: Safety Precautions

    Refer to the diagrams and illustrations employer, local, government shown elsewhere in this manual for requirements for safe work practices correct handling procedures using a near energised equipment. crane and forklift. 1001281353 JLG Industries (Australia) Pty Ltd Page 1-7 Oshkosh Corporation 28JUL22...
  • Page 8 LED floodlights If need be, place suitable packing supplied. Alternative lights should not material such as hardwood timber be fitted unless authorised by JLG. offcuts under each jack distribute the lighting tower’s weight 2.
  • Page 9 Frame Telescopic Mast Mast Cable Chute Tie-Down Point Fire Extinguisher Outrigger Arm Control Panel Door Levelling Jack Fuel Tank Access Door Fork Pockets Figure 1.3.1 JLG LT Lighting Tower 1001281353 JLG Industries (Australia) Pty Ltd Page 1-9 Oshkosh Corporation 28JUL22...
  • Page 10 Access Door Engine/Genset Figure 1.3.2 JLG LT Lighting Tower Access Door Emergency Mast / Lighthead Stop Button V-rest Operation & Safety Manual Storage Box Figure 1.3.3 JLG LT Lighting Tower 1001281353 JLG Industries (Australia) Pty Ltd Page 1-10 Oshkosh Corporation 28JUL22...
  • Page 11 Service  Light-head LED fixture pivots and Maintenance) for procedures relating to swivel connections are done-up tight. regular and periodic machine inspections 6. Check and drain bunding if necessary. 1001281353 JLG Industries (Australia) Pty Ltd Page 1-11 Oshkosh Corporation 28JUL22...
  • Page 12: Machine Controls

    Release switch to lock lighthead rotation. Option 2 Electro-Mechanical Slew-Drive combined with Slip-Ring. This slew-drive allows the lighthead to rotate ±360°. The slew-drive is operated by control-panel toggle-switch and enable button. 1001281353 JLG Industries (Australia) Pty Ltd Page 1-12 Oshkosh Corporation 28JUL22...
  • Page 13 MODULE TO SHUT DOWN THE ENGINE. Fig 1.4.3 Control Panel Machine Manuals Storage Box Sight Bubble Level Fig 1.4.5 Emergency Stop Location EMERGENCY STOP Fig 1.4.4 Bubble-Level Location Fig 1.4.6 Component Locations Battery Isolator 1001281353 JLG Industries (Australia) Pty Ltd Page 1-13 Oshkosh Corporation 28JUL22...
  • Page 14: Machine Operation

    It is not necessary to raise the lighting tower’s base above the ground when setting the outrigger jacks. When set up correctly the base may still make firm contact. Fig 1.5.2 1001281353 JLG Industries (Australia) Pty Ltd Page 1-14 Oshkosh Corporation 28JUL22...
  • Page 15 LED Light Tilt Adjustment Fig 1.5.6 LED Light Trunnion Rotation 3. Hold the light trunnion in position when retightening the M16 nyloc nut. Fig 1.5.4 LED Light Tilt Adjustment 1001281353 JLG Industries (Australia) Pty Ltd Page 1-15 Oshkosh Corporation 28JUL22...
  • Page 16 3. To raise mast to the required height, 2) Auto Start/Stop press the enable button and at same time, toggle the mast raise/lower A summary of each control mode follows. switch ‘up’. 1001281353 JLG Industries (Australia) Pty Ltd Page 1-16 Oshkosh Corporation 28JUL22...
  • Page 17 If the alarm re-triggers in mute status, the controller will remove the mute status. 1001281353 JLG Industries (Australia) Pty Ltd Page 1-17 Oshkosh Corporation 28JUL22...
  • Page 18 2) Auto Start/Stop Mode - Summary stopping. A) press for each screen shown in Fig 1 to Fig 3 press to select press to confirm 1001281353 JLG Industries (Australia) Pty Ltd Page 1-18 Oshkosh Corporation 28JUL22...
  • Page 19 Parameter Setting 01 Timer Start Start Time Duration 18:50 08:30 Press the key to confirm setting and the set value will be saved into internal FLASH 1001281353 JLG Industries (Australia) Pty Ltd Page 1-19 Oshkosh Corporation 28JUL22...
  • Page 20 Before transporting, ensure that V-arm attached to the top of mast section 6 seats in the V-plate bolted to mast section 1 Fig 1.5.13 LT Stowed. V-arm V-plate Fig 1.5.12 1001281353 JLG Industries (Australia) Pty Ltd Page 1-20 Oshkosh Corporation 28JUL22...
  • Page 21 Before lifting and moving the lighting tower, ensure both forklift tynes protrude at least 800 mm into the fork pockets. Fork pocket opening: 90 mm x 190 mm Fork pocket centres: 680 mm Figure 1.6.2 1001281353 JLG Industries (Australia) Pty Ltd Page 1-21 Oshkosh Corporation 28JUL22...
  • Page 22 Do not over tension the chain or strap. Check the load restraint system regularly when travelling long distances, especially over rough sealed and unsealed roads. Figure 1.6.4 LT Two-Abreast Tie-Down Restraint 1001281353 JLG Industries (Australia) Pty Ltd Page 1-22 Oshkosh Corporation 28JUL22...
  • Page 23 Figure 1.7.1 LT Stored Configuration Clean exterior surfaces remove any collected or accumulated plant or leaf matter 1001281353 JLG Industries (Australia) Pty Ltd Page 1-23 Oshkosh Corporation 28JUL22...
  • Page 24: Machine Specification

    From Maximum Height 1.465 m to Stowed Position 15 s Lighthead Tilt 0 - 40° 15 s Figure 1.8.1 JLG LT lighting tower Lighthead Rotation 0 - 360° 30 s (electro-mechanical) 1001281353 JLG Industries (Australia) Pty Ltd Page 1-24 Oshkosh Corporation 28JUL22...
  • Page 25 IP 66 1.18 m Electrical System Protection 1.18 m System Accessories Circuit 1 x 15 A Figure 1.8.2 JLG LT shown “stowed’. Lighting Circuit Breakers 4 x 10 A 1001281353 JLG Industries (Australia) Pty Ltd Page 1-25 Oshkosh Corporation 28JUL22...
  • Page 26: Lighthead Isolux Plots

    Oshkosh Corporation Classification ‐ Restricted  LIGHTHEAD ISOLUX PLOTS JLG LT Chart 1.9.1 Lighthead Tilt Angle 0° Chart 1.9.2 Lighthead Tilt Angle 45° 1001281353 JLG Industries (Australia) Pty Ltd Page 1-26 Oshkosh Corporation 28JUL22...