3289 Text Print Control; 3274 Model Designation; Color; Structured Field And Attribute Processing (Sfap) (Configuration Support Conly) - IBM 3274 Planning, Setup, And Customizing Manual

Information display system
Hide thumbs Also See for 3274:
Table of Contents

Advertisement

ModellA
145 3289 Text Print Control
147
151 3274 Model Designation
161 Color
Enter a 0 if no 3289 Line Printer is attached or if a 3289 without the Text Print Chain is
attached. Enter a 1 if a 3289 with the Text Print Chain is attached.
Enter a 1 for this sequence number in step 8 on the customizing form. This function is
not selectable on the ModellA and is automatically included in your configuration.
Enter an A to specify the 3274 Model lA.
Enter 0 if no color display terminals or printers are attached; enter 1 if any are.
162 Structured Field and Attribute Processing (SFAP)
(Configuration Support COnly)
Enter a
1
if SF
AP
is being used; enter a
0
if not. This feature is necessary if you are using
the write-structured field command or any of the following orders: set attribute, start
field extended, modify field.
If you enter a 0,163-166 will not be asked.
163 Extended Character Set Adapter
(Configuration Support COnly)
This is the number of terminals with the extended character set adapter installed. A
2-digit number must be entered. If necessary, use a leading zero. For example, to specify
8, enter 08.
For Model IC, this number must not exceed the number of Category A terminals
specified in sequence number 112.
164 Programmed Symbols (PS) (Configuration
Support COnly)
Enter a 1 if your system has PS terminals; enter a 0 if not.
165 Decompression (Configuration Support COnly)
Enter a 1 if you specified PS data for 164 and want to send compressed PS data; enter a 0
otherwise. (Not asked unless 1 was specified for 164)
166 Advanced Function Keyboard (Configuration
Support COnly)
201 Control Unit Address
211 SCS Support
3-8
Enter one of the following to specify the function of the program function keys in upper
shift.
A
=
No advanced functiort keyboards being used.
B
=
Advanced function keyboards without the numeric lock feature
C
=
Advanced function keyboards with the numeric lock feature (#4690)
Enter the 2-character hexadecimal control unit address; this information can be obtained
from the system programmer at the host system location. The host system recoghizes this
address as the input/output address.
Enter a 0 if the SNA character string (SCS) feature (#9660) is not installed on any
attached printer, or a 1 if it is.

Advertisement

Table of Contents
loading

This manual is also suitable for:

3270

Table of Contents