Models
lC
and
SlC)
031 RPQ Diskettes Required
Refer to Appendix C for detailed information on the parameters of the printer
authorization matrix.
Fill in the appropriate spaces on the Printer Authorization Matrix Form with a definition
for each printer in your configuration, and attach it to the Initial Customizing Procedures
Form to give to the operator who will perform the customizing procedure. The
definitions may be entered in any sequence. Also, definitions do not have to be entered
successively; for example, you may enter definitions in groups 1, 2, and 3 of the form,
skip groups 4 and 5, and continue at group 6.
Once a printer authorization matrix has been defined, sequence number 021 is no longer
displayed when a customized 3274 Control Unit is being updated. Instead, the defined
matrix is displayed. If the entire matrix is deleted, sequence number 021 will again be
displayed during each updating procedure until a new matrix is defined. Any time the
initial customizing procedure is performed, the sequence number 021 is displayed and the
printer authorization matrix must be redefined if it is still required.
Enter the number of RPQ diskettes required (1-3) in step 7 of the Initial Customizing
Procedures Form. Enter a 0 if none are required.
111 Number of Category B Terminals
3-18
Enter a 2-digit number (00 to 16) specifying the number of Category B terminals that it is
possible to attach to your 3274. (The actual number you have attached at any given time
may be fewer than this number.)
Notes:
1. A 2-digit number must be entered. If necessary, use a leading zero. For example, to
specify 8, enter 08.
2. Category A terminals:
3278 Models 1, 2, 3,4, and 5
3279 Models 2A, 2B, 3A, and 3B
3287 Models 1 C and 2C
3287 Models 1 and 2 with 3274/3276 attachment (#8331)
3289 Models 1 and 2
Category B terminals
3277 Models 1 and 2
3284 Models 1 and 2
3286 Models 1 and 2
3287 Models 1 and 2 with 3271/3272 attachment (#8330)
3288 Model 2
3a. Specify the number of Category A terminals in mUltiples of 8 (maximum of 32 for
the 1C, 8 for the 51C) and the number of Category B terminals in mUltiples of 4
(maximum of 16 for the 1e, 4 for the 51C), unless the sum of the two categories
exceeds 32.
3b. If the sum of the two categories exceeds 32:
• For Category B terminals, specify the actual number of Category B terminals
(sequence number 111 ).
• For Category A terminals, specify the difference between 32 and the number of
Category B terminals (sequence number 112).