Rpq Diskettes Required; Number Of Category B Terminals - IBM 3274 Planning, Setup, And Customizing Manual

Information display system
Hide thumbs Also See for 3274:
Table of Contents

Advertisement

031 RPQ Diskettes Required
Models 1 B and 1 D
Refer to Appendix, C for detailed information on the parameters of the printer
authorization matrix.
Fill in the appropriate spaces on the Printer Authorization Matrix Form with a definition
for each printer in your configuration, and attach it to the Initial Customizing Procedure
Form to give to the operator who will perform the customizing procedure. The
definitions may be entered in any sequence. Also, definitions do not have to be entered
successively; for example, you may enter definitions in groups 1, 2, and 3 of the form,
skip groups 4 and 5, and continue at group 6.
Once a printer authorization matrix has been defined, sequence number 021 is no longer
displayed when a customized 3274 Control Unit is being updated. Instead, the defined
matrix is displayed. If the entire matrix is deleted, sequence number 021 will again be
displayed during each updating procedure until a new matrix is defined. Any time the
initial customizing procedure is performed, the sequence number 021 is displayed and the
printer authorization matrix must be redefined if it is still required.
Enter the number of
RPQ
diskettes required (1-3) in step 7 of the Initial Customizing
Procedures Form. Enter a 0 if none are required.
111 Number of Category B Terminals
Enter a 2-digit number (00 to 16) specifying the number of Category B terminals that it is
possible to attach to your 3274. (The actual number you have attached at any given time
may be fewer than this number.)
Notes:
1. A 2·digit number must be entered. If necessary, use a leading zero. For example, to
specify
8,
enter 08.
2. Category A terminals:
3278 Models 1, 2, 3, and 4
3279 Models 2A, 2B, 3A, and 3B
3287 Models
1
and
2
with
3274/3276
attachment
(#8331)
3287 Models
1 C
and
2C
3289 Models 1 and 2
Category B terminals
3277 Models 1 and 2
3284 Models
1
and 2
3286 Models
1
and 2
3287 Models
1
and
2
with
3271/3272
attachment (#8330)
3288
Model
2
3a. Specify the number of Category A terminals in multiples of
8
(maximum of
32)
and
the number of Category B terminals in multiples of 4 (maximum of
16),
unless the
sum of the two categories exceeds 32.
3b. If the sum of the two categories exceeds 32:
• For Category B terminals, specify the actual number of Category B terminals
(sequence number
111 ).
• For Category A terminals, specify the difference between
32
and the number of
Category B terminals (sequence number
112).
Chapter 3. Preparing to Customize
3·11

Advertisement

Table of Contents
loading

This manual is also suitable for:

3270

Table of Contents