IBM 3274 Planning, Setup, And Customizing Manual page 94

Information display system
Hide thumbs Also See for 3274:
Table of Contents

Advertisement

Code
Meaning
Action
01
One or more of the first 10 characters is incorrect.
Enter the correct response.
02
One or more of the 11 th to 17th characters, including
Enter the correct response.
the space, is incorrect.
03
(1 )
One of the last two characters you entered in
(1 )
Enter the correct response.
response to sequence number 001 is incorrect, or,
(2)
the diskette release level is not the same
(2)
Restart after matching
as the documentation level.
diskette and documentation
levels.
11
You entered an invalid response (too many characters,
Enter the correct response.
value too high or too low, wrong character, etc.).
12
You entered a character other than A, B, C,
0,
or E in
Enter the correct response.
response to sequence number 151.
13
Your response has too few characters.
Enter the correct response.
14
( 1)
The numerical sum of the responses you entered
(1)
Enter the correct response.
for sequence numbers 111 and 112is greater
than 32.
(2)
Your response to #163 is greater than your
(2)
Enter the same or less than
response to #112.
your response to #112.
21*
You made an unacceptable change during the modify
Recheck the entries and correct
sequence (number 999l.
them.
22*
( 1)
Your response to sequence number 321 is 1, but
(1)
Verify and enter the correct
121 is not 02 and/or 131 is not 1, or
response.
(2)
321 is 0 and 121 is 02.
(2)
Verify and enter the correct
response.
23*
One or more of your responses are not compatible
Verify and enter the correct
with the response to sequence number 331.
response.
24*
(1)
All of your responses to sequence numbers 131
(1 )
Verify and enter the correct
through 135 are Os (at least one response must
response (sl.
be a
1),
or,
(2)
Your response to sequence number 113 was 3622
(2)
Verify and enter the correct
but the extended function store feature is not
response.
installed in the 3274.
25*
(1 )
If this is response to sequence number 133, you
(1)
Verify and enter the correct
specified Katakana in 121 and Data Entry Key-
response.
punch keyboard in 133. (There is no Data Entry
Keypunch keyboard for Katakana.)
(2)
If th is is response to sequence number 113, the
(2)
Notify your supervisor.
3274 has insufficient storage.
26*
I nsufficient storage in the 3274.
Notify your supervisor.
27
(1)
Language 18 specified for sequence
( 1)
Change response to sequence
number 121 not allowed.
number 121 to 28.
(2) Alternate language specified for sequence number
(2) Change response to sequence
121 and SFAP specified for sequence number 162.
number 121 to a non-
alternate language or
specify 0 for sequence
numbers 162, 164, and
165 or
specify A for sequence
number 166 or
specify 00 for sequence
number 163.
99
Your entries are acceptable, but the entry for sequence
Change 900 or 901 entry to
number 900 or 901 has not been changed to a 1.
a 1.
*If any entry is unacceptable, the entry for sequence number 900 is changed back to 0 (zero) and
the unacceptable value is intensified.
Figure 54. Operator Codes During the Modification Procedure
Only
Chapter 5. Modification Procedure
5·11

Advertisement

Table of Contents
loading

This manual is also suitable for:

3270

Table of Contents